IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v11y2018i5p1076-d143525.html
   My bibliography  Save this article

Blood Volume Pulse Extraction for Non-Contact Heart Rate Measurement by Digital Camera Using Singular Value Decomposition and Burg Algorithm

Author

Listed:
  • Iman Rahmansyah Tayibnapis

    (Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea)

  • Yeon-Mo Yang

    (Department of Electronic Engineering, Kumoh National Institute of Technology, Gumi 39177, Korea)

  • Ki Moo Lim

    (Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea)

Abstract

Conventional photoplesthymograph (PPG) measurements for heart rate (HR) determination require direct contact between the patient and the PPG device sensor. When using the conventional method, it is possible for users to suffer undesirable skin irritation, discomfort and soreness. Thus, the development of non-contact PPG has been investigated with various technologies and methods. One of the technologies that able to measure PPG in a non-contact way and at low cost is using digital cameras such as webcams. Various filters have been implemented to do non-contact PPG using digital cameras. This paper proposes a non-contact PPG filter system utilizing singular value decomposition (SVD) and Burg’s algorithm. The main role of SVD is for noise removal and as PPG signal extractor. As for the Burg algorithm, it was utilized for estimating the heart rate value from the filtered PPG signal. In this paper, we show and analyze an experiment for HR measurement using our method and a previous method that used independent component analysis (ICA). We compare and contrast both of them with HR measurements acquired by a commercial oximeter. The experiments were conducted at various distance between 30~110 cm and light intensities between 5~2000 lux. The estimated HR showed 2.25 bpm of mean error and 0.73 of Pearson correlation coefficient. The optimal distance between the mirror and user for HR measurement was 50 cm with medium light intensity, around 550 lux.

Suggested Citation

  • Iman Rahmansyah Tayibnapis & Yeon-Mo Yang & Ki Moo Lim, 2018. "Blood Volume Pulse Extraction for Non-Contact Heart Rate Measurement by Digital Camera Using Singular Value Decomposition and Burg Algorithm," Energies, MDPI, vol. 11(5), pages 1-9, April.
  • Handle: RePEc:gam:jeners:v:11:y:2018:i:5:p:1076-:d:143525
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/11/5/1076/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/11/5/1076/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:11:y:2018:i:5:p:1076-:d:143525. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.