Author
Listed:
- Sebastian F. Noller
(Faculty 2: School of Engineering—Technology and Life, University of Applied Science (HTW) Berlin, 12459 Berlin, Germany)
- Roland Heiler
(Faculty 2: School of Engineering—Technology and Life, University of Applied Science (HTW) Berlin, 12459 Berlin, Germany)
- Anja Pfennig
(Faculty 2: School of Engineering—Technology and Life, University of Applied Science (HTW) Berlin, 12459 Berlin, Germany)
Abstract
The production of staple articles such as cable ducts offers reductions in resource and production energy consumption if the process is optimized. Side recesses made of polyvinyl chloride (PVC) have already been punched successfully as one of the process steps during the production of cable ducts. However, punching cable ducts made of flame-retardant polycarbonate/acrylonitrile–butadiene–styrene (PC/ABS) is challenging because increased burr and film formation occurs. This study introduces the correct dimensioning of the clearance as a means of reducing the burr and film formation and presents the ideal clearance dimensions. This new process design approach comprises the dimensioning of the clearance and its subsequent successful application. Tools with clearances in the relevant size range were purchased and examined by means of punching tests. The punch-outs were evaluated regarding the quality characteristics, such as the burr, film, cut surface quality, shear droop, and plastic flow characteristics. Excerpts from high-speed recordings were used to assess the punch-outs qualitatively. The burr formation is significantly decreased by the use of a correctly dimensioned clearance, allowing for the crack initiated at the punch side and the crack initiated at the die side to meet perfectly. It is assumed that film formation can be avoided via a significant reduction in the friction or heat input during the punching process.
Suggested Citation
Sebastian F. Noller & Roland Heiler & Anja Pfennig, 2022.
"Dimensioning of the Clearance as a Means of Avoiding Burr and Film Formation during the Punching of PC/ABS Cable Ducts,"
Clean Technol., MDPI, vol. 4(4), pages 1-10, December.
Handle:
RePEc:gam:jcltec:v:4:y:2022:i:4:p:79-1299:d:1002725
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jcltec:v:4:y:2022:i:4:p:79-1299:d:1002725. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.