Mammography is a special type of radiography for the breast, to increase the contrast in breast images, mammography uses much lower X-ray energy compared to general radiography. Mammography is the best technology available for early detection of breast cancer. Image quality is one of the main things to consider in viewing the quality of mammography. This study aims to analyze the effect of radiation projection on image quality in mammography images using the Signal to Noise Ratio (SNR) parameter so as to produce the highest Signal to Noise Ratio (SNR) value for Mediolateral oblique (MLO) and Craniocaudal (CC) radiation projections. The study was conducted based on secondary data from mammography examinations of Right-Craniocaudal (RCC), Left-Craniocaudal (LCC), Right-Mediolateral oblique (RMLO), and Left-Mediolateral oblique (LMLO) radiation projections at Persahabatan Hospital, the exposure factor chosen was the exposure factor that had the most data, namely at a tube voltage of 28 kV. The results of the study showed that the overall average SNR results were obtained for each projection, namely the highest SNR value of 10,68 in the Left-Craniocaudal projection, while the lowest SNR was 8,84 in the Right-Mediolateral oblique projection. The CC projection provided images with higher SNR values, resulting in better image quality, while the MLO projection was still needed to obtain wider breast tissue coverage.
Suggested Citation
Vivi Al Fara & Zaenal Arifin & Evi Setiawati, 2025.
"Analysis of the Effect of Irradiation Projection on the Signal-to-Noise Ratio in Mammography Images,"
International Journal of Scientific Research in Science and Technology, Technoscience Academy, vol. 12(3), pages 809-814, June.
Handle:
RePEc:etm:ijsrst:v12:y2025:i3:id:896
DOI: 10.32628/IJSRST25123089
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:etm:ijsrst:v12:y2025:i3:id:896. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Pankaj Sharma (email available below). General contact details of provider: https://ijsrst.com/home .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.