Author
Listed:
- Elisabet Turnip
- Evi Setiawati
- Pandji Triadyaksa
- Mohamad Hidayatullah
Abstract
In the Treatment Planning System (TPS), when the patient is irradiated with one direction of radiation, the Organ At Risk (OAR) around the Planning Target Volume (PTV) receives a high dose and receives an uneven dose. By considering the dose distribution on the PTV and OAR, it is necessary to determine the appropriate radiation direction on the TPS. This study compares the radiation dose achieved by the PTV and OAR of breast cancer patients with radiation directions 3, 5, 7, and 9 on the TPS Intensity Modulated Radiation Therapy (IMRT). This study used 16 retrospective data sets of breast cancer patients consisting of 8 patient data without breast surgery and 8 post-breast surgery data. The data obtained in this study were V95, D2%, D50%, and D98% from the DVH graph. Data analysis was carried out by comparing the average values of the Conformity Index (CI) and Homogeneity Index (HI) and the average dose received by the OAR in four variations of radiation directions. In breast cancer patients without surgery, better CI values were obtained in 9 radiation directions with an average CI = 0.980424; the lowest CI value = 0.957054 and the highest CI value = 0.998541. While in post-operative breast cancer patients, better CI values were obtained in 7 radiation directions with an average CI = 0.983920; the lowest CI value = 0.928394 and the highest CI value = 0.999994. In breast cancer patients without surgery, better HI values were obtained in 9 radiation directions with an average HI = 0.153551; the lowest HI value = 0.086190, and the highest HI value = 0.209303. While in post-operative breast cancer patients, better HI values were obtained in 7 radiation directions with an average HI = 0.121777; the lowest HI value = 0.081539, and the highest HI value 0.158169. The mean dose received by OAR of breast cancer patients without surgery was achieved in 9 radiation directions. In contrast, in post-operative breast cancer patients, it was completed in 5, 7, and 9 radiation directions. Reviewed from the conformity factor (CI) and uniformity (HI), and the mean dose received by breast cancer patients, it can be concluded that planning using IMRT with 9 radiation directions is optimal for use in breast cancer patients without surgery. While radiation with 7 directions is optimal for use in post-operative breast cancer patients. With higher conformity, lower homogeneity, and PTV receiving the maximum dose, the dose received by OAR can be minimized.
Suggested Citation
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:etm:ijsrst:v12:y2025:i3:id:867. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Pankaj Sharma (email available below). General contact details of provider: https://ijsrst.com/home .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.