Assessment of Low-Contrast Detectability on ACR CT Phantom with Variations in Tube Voltage and Object Size Using 2-AFC Method

Author

Listed:
  • Siti Silfa Mislaeni
  • Choirul Anam
  • Jatmiko Endro Suseno
  • Ngurah Ayu Ketut Umiati
  • Ariij Naufal
  • Riska Amilia
  • Rahmat Riyadi

Abstract

This study aims to assess low-contrast detectability (LCD) in the American College of Radiology (ACR) computed tomography (CT) phantom at various tube voltages and object sizes using the two-alternative forced choice (2-AFC) method. The experiment was conducted using the low-contrast module, which contains objects with contrast of 6 HU and with diameters of 2, 3, 4, 5, and 6 mm. The phantom was scanned using a Philips CT scanner at three tube voltage settings: 90 kV, 120 kV, and 140 kV. Two region of interests (ROIs) were created for both the object and background and displayed through the IndoQCT software, resulting in 300 randomly paired images (questions). These images were independently assessed by seven medical physicists with over two years of clinical experience to identify the presence of low-contrast objects. The IndoQCT software automatically calculated the Percent Correct (PC) for each respondent, and the LCD performance was analyzed based on these PC values. The results showed that larger object sizes corresponded with improved detection performance. The 90 kV setting yielded optimal detection for larger objects (i.e., 5 and 6 mm), while 120 kV was more effective for smaller objects (i.e., 2–4 mm). Conversely, 140 kV resulted in the lowest detection performance across all object sizes. These findings suggest that lower tube voltages can enhance LCD despite increased image noise. Additionally, the variability among observers was minimal, with a p-value >0,5 indicating no significant differences in their ability to assess LCD.

Suggested Citation

  • Siti Silfa Mislaeni & Choirul Anam & Jatmiko Endro Suseno & Ngurah Ayu Ketut Umiati & Ariij Naufal & Riska Amilia & Rahmat Riyadi, 2025. "Assessment of Low-Contrast Detectability on ACR CT Phantom with Variations in Tube Voltage and Object Size Using 2-AFC Method," International Journal of Scientific Research in Science and Technology, Technoscience Academy, vol. 12(2), pages 1172-1180, April.
  • Handle: RePEc:etm:ijsrst:v12:y2025:i2:id:772
    DOI: 10.32628/IJSRST251222676
    as

    Download full text from publisher

    File URL: https://ijsrst.com/home/article/view/IJSRST251222676
    File Function: Abstract page
    Download Restriction: no

    File URL: https://ijsrst.com/home/article/download/IJSRST251222676/IJSRST251222676
    File Function: Full text
    Download Restriction: no

    File URL: https://libkey.io/10.32628/IJSRST251222676?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:etm:ijsrst:v12:y2025:i2:id:772. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Pankaj Sharma (email available below). General contact details of provider: https://ijsrst.com/home .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.