Author
Listed:
- Sami Smerat
(Istishari Arab Hospital, Palestine)
- Azzam Alarab
(Ahliya University, Palestine)
- Maram Ghassan Sada
(Al-Quds University, Palestine)
- Issa Al Hroush
(Istishari Arab Hospital, Palestine)
- Marah Abu Muhsen
(Istishari Arab Hospital, Palestine)
- Murad Abu Samra
(Icahn School of Medicine, Mount Sinai, USA)
- Moath Al-Makhamreh
(Yatta Public Hospital, Palestine)
- Sojood Mansour
(Al-Quds University, Palestine)
- Mohammad Almashny
(Istishari Arab Hospital, Palestine)
- Hasan Naji
(Istishari Arab Hospital, Palestine)
- Mohammed Hjouj
(Al-Quds University, Palestine)
Abstract
Purpose: The purpose of this retrospective study was to compare the ability of indirect 128-row multidetector CT (MDCT) venography and doppler sonography to detect deep vein thrombosis (DVT) after knee or hip arthroplasty. Methods and Materials: Replacement surgery was performed on a total of ten hip and sixty-eight knee joints in 52 patients. The evaluation of the presence of DVT is degraded by the beam hardening artifact; therefore, Axial CT images could not be used to assess DVT. The beam hardening artifact's z-axis length was measured. Deep vein thrombosis was studied to see how common it is and where it occurs. The CT venograms' diagnostic performance was assessed and compared to that of the gold standard diagnostic reference for DVT: doppler sonography. Results: The beam hardening artifact had a z-axis length of 6.0 (mean standard deviation). Doppler sonography is a technique that allows you to see what's going on inside your body. In 30/52 individuals, DVT was found in the calf veins (58 percent of total population). The binary scale diagnostic test revealed that CT venography and doppler sonography had sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 93.33 percent, 90.91 percent, 90.91 percent, and 92.31 percent, respectively. Conclusion: For the aim of evaluating post-arthroplasty patients, CT venography can be utilized as a substitute for doppler sonography.
Suggested Citation
Sami Smerat & Azzam Alarab & Maram Ghassan Sada & Issa Al Hroush & Marah Abu Muhsen & Murad Abu Samra & Moath Al-Makhamreh & Sojood Mansour & Mohammad Almashny & Hasan Naji & Mohammed Hjouj, 2022.
"Assessment of Deep Vein Thrombosis Using Multidetector Computed Tomography After Arthroplasty: A Retrospective Comparative Study with Doppler Sonography,"
European Journal of Medical and Health Sciences, European Open Science, vol. 4(6), pages 32-38, October.
Handle:
RePEc:epw:ejmed0:v:4:y:2022:i:6:id:41150
DOI: 10.24018/ejmed.2022.4.6.1150
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:epw:ejmed0:v:4:y:2022:i:6:id:41150. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Support (email available below). General contact details of provider: https://eu-opensci.org/index.php/ejmed .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.