IDEAS home Printed from https://ideas.repec.org/a/epw/ejmed0/v3y2021i4id40849.html

Assessing the Status of Quality Control Parameters of Four Computed Tomography Scanners in Ibadan

Author

Listed:
  • Osayaba Peace Egharevba

    (Nnamdi Azikiwe University, Nigeria)

  • Christian Chukwuemeka Nzotta

    (Nnamdi Azikiwe University, Nigeria)

  • Emmanuel Oyeyemi Oyekunle

    (University College Hospital, Nigeria)

  • Mohammed Anas

    (State Specialist Hospital, Nigeria)

Abstract

Background: Quality control (QC) of computed tomography (CT) scanners is important to evaluate succinctly quality image and radiation dose obtainable in a clinical environment. The aim of this study was to evaluate the quality of images generated by CT scanners used at some diagnostic facilities in Ibadan, Nigeria. Materials and Methods: A cross sectional design was employed in this study, four centers were studied, one government hospital and three private hospitals. The head CT phantom was used to verify the accomplishment of the CT scanners performance to the international quality requirements. Regions of interest were selected at the center of the image and at the periphery to obtain results for the CT number for water test, uniformity test, noise, and artifact test. Results: The mean CT number for water across the centers ranged from –0.12 HU to –2.2 HU which were within ±3 HU recommended by the equipment manufacturer. Values of standard deviation of the mean CT number ranged from 2.41 to 5.77 HU which to a little extent exceeded the set ±5 HU tolerance range. Similarly, the presence of streak artifact was observed in the images obtained at one center. Conclusion: Two out of the four computed tomography scanners assessed passed the four tests performed. Noise and artifact were the problem observed at centers B and C respectively. There was however no likelihood of periodic performance of these basic quality control tests at two of the centers in this study. Adequate records of quality control data should be kept regularly to allow in-depth analysis of failure rates of different tests, changes occurring during equipment lifetime and comparisons among CT scanners.

Suggested Citation

  • Osayaba Peace Egharevba & Christian Chukwuemeka Nzotta & Emmanuel Oyeyemi Oyekunle & Mohammed Anas, 2021. "Assessing the Status of Quality Control Parameters of Four Computed Tomography Scanners in Ibadan," European Journal of Medical and Health Sciences, European Open Science, vol. 3(4), pages 80-83, July.
  • Handle: RePEc:epw:ejmed0:v:3:y:2021:i:4:id:40849
    DOI: 10.24018/ejmed.2021.3.4.849
    as

    Download full text from publisher

    File URL: https://eu-opensci.org/index.php/ejmed/article/view/40849
    File Function: Abstract page
    Download Restriction: no

    File URL: https://eu-opensci.org/index.php/ejmed/article/download/40849/9326
    File Function: Full text
    Download Restriction: no

    File URL: https://libkey.io/10.24018/ejmed.2021.3.4.849?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Keywords

    ;
    ;
    ;

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:epw:ejmed0:v:3:y:2021:i:4:id:40849. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Support (email available below). General contact details of provider: https://eu-opensci.org/index.php/ejmed .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.