Abstract
This article forecasts the performance of smart-grid electrical transmission systems and integrated battery/FC/Wind/PV storage system renewable power sources in the context of unpredictable solar and wind power supplies. The research provided a hybrid renewable energy sources smart grid power system electrical frequency control solution using adaptive control techniques and model predictive control (MPC) based on the Multi-Objective Practical Swarm Optimization Algorithm MOPSO. To solve the problems of parameter tuning in Load Frequency Control, the suggested adaptive control approach is utilized to accomplish on-line adjustment of the Load Frequency Control parameters. During the electrical grid's integration, the system under investigation is a hybrid Wind/PV/FC/Battery smart grid with variable demand load. To achieve optimal outcomes, all of the controller settings for various units in power grids are determined by means of a customized objective function and a particle swarm optimization method rather than a regular objective function with fluctuating restrictions. To suppress the consumption and generation balance, MPCs were designed for each of the Storage Battery, Wind Turbine Generation, and the model Photovoltaic Generation. In addition, demand response (real-time pricing) was used in this scheme to reduce the load frequency by adjusting the controlled loads. The suggested control strategy is evaluated in the Simulink /MATLAB environment in order to analyse the suggested approach's working in the power system, as well as its effectiveness, reliability, robustness, and stability. The simulation findings show that the proposed control method generally converges to an optimal operating point that minimises total user disutility, restores normal frequency and planned tie-line power flows, and maintains transmission line thermal restrictions. The simulation results further indicate that the convergence holds even when the control algorithm uses inaccurate system parameters. Finally, numerical simulations are used to illustrate the proposed algorithm's robustness, optimality, and effectiveness. In compared to previous methodologies, the system frequency recovers effectively and efficiently in the event of a power demand disturbance, as demonstrated. A sensitivity test is also performed to assess the suggested technique's effectiveness.
Suggested Citation
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:epw:ejeng0:v:6:y:2021:i:5:id:62507. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Support (email available below). General contact details of provider: https://eu-opensci.org/index.php/ejeng .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.