IDEAS home Printed from https://ideas.repec.org/a/caa/jnlswr/v3y2008i4id18-2008-swr.html
   My bibliography  Save this article

Field and laboratory ad hoc calibrations of Virrib and ThetaProbe dielectric sensors for soil moisture measurements

Author

Listed:
  • František Doležal

    (Research Institute for Soil and Water Conservation, Prague, Czech Republic)

  • Tomáš Litschmann

    (AMET - Consortium Litschmann-Suchý, Velké Bílovice, Czech Republic)

  • Jiří Kučera

    (Environmental Measuring Systems, Brno, Czech Republic)

  • Jana Peterková

    (Research Institute for Soil and Water Conservation, Prague, Czech Republic)

  • Josef Zavadil

    (Research Institute for Soil and Water Conservation, Prague, Czech Republic)

  • Josef Vacek

    (Potato Research Institute Havlíčkův Brod Ltd., Havlíčkův Brod, Czech Republic)

  • Pavel Pražák

    (Research Institute for Soil and Water Conservation, Prague, Czech Republic)

  • Eva Pilná

    (Research Institute for Soil and Water Conservation, Prague, Czech Republic)

  • Tomáš Bayer

    (Research Institute for Soil and Water Conservation, Prague, Czech Republic)

  • Marek Nechvátal

    (Research Institute for Soil and Water Conservation, Prague, Czech Republic)

Abstract

For the research of irrigation optimization and nitrate leaching it is important to know the short-term soil moisture variation during percolation episodes as well as its seasonal pattern. Dielectric soil moisture sensors Virrib (AMET - Consortium) and ThetaProbe ML2x (Delta-T) were used for this purpose over several years for measuring soil moisture content at hourly intervals in Valečov (49°38'40" N, 14°30'25" E, 461 m a.s.l.), Czech Republic, in a deep loamy Stagnosol soil underlain by weathered paragneiss. One-point field calibration was made each spring at the time of sensor installation over three (for Virribs) or two (for ThetaProbes) consecutive years by taking sensor readings and soil samples (at least one 100 cm3 core sample near to each sensor) in parallel. A supplementary check was then made in the laboratory by taking readings of individual sensors, inserted into pre-made loamy-sand mixtures with various moisture contents. During both the field calibration and the laboratory check, the readings were taken manually, using either the AMET hand-held meter or the EMS ModuLog datalogger. The results suggest that the average slope of the secondary Virrib calibration curve (defined as the plot of y = sensor readings in terms of moisture content vs. x = soil moisture content determined gravimetrically) is near to unity, but the offsets are quite large and vary from probe to probe. The axial zone of influence of the Virrib sensors is up to about 30 cm, as it follows from both laboratory and field observations. The results of the laboratory check of Virribs were biased, because the volume of the soil was not large enough and the soil had different dry bulk densities at different moisture contents. The field secondary calibration curve of ThetaProbes appears to be roughly linear, in contrast to the laboratory calibration curve, because of absence of very low moisture contents in the field. If the same calibration line is applied to several different depths, then its slope is statistically significantly lower then unity, due to the dependence of ThetaProbe readings on the soil bulk density. The overall accuracy of the sensors and its components due to different factors is estimated from the statistics of repeated measurements.

Suggested Citation

  • František Doležal & Tomáš Litschmann & Jiří Kučera & Jana Peterková & Josef Zavadil & Josef Vacek & Pavel Pražák & Eva Pilná & Tomáš Bayer & Marek Nechvátal, 2008. "Field and laboratory ad hoc calibrations of Virrib and ThetaProbe dielectric sensors for soil moisture measurements," Soil and Water Research, Czech Academy of Agricultural Sciences, vol. 3(4), pages 199-214.
  • Handle: RePEc:caa:jnlswr:v:3:y:2008:i:4:id:18-2008-swr
    DOI: 10.17221/18/2008-SWR
    as

    Download full text from publisher

    File URL: http://swr.agriculturejournals.cz/doi/10.17221/18/2008-SWR.html
    Download Restriction: free of charge

    File URL: http://swr.agriculturejournals.cz/doi/10.17221/18/2008-SWR.pdf
    Download Restriction: free of charge

    File URL: https://libkey.io/10.17221/18/2008-SWR?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Radka Kodešová & Vít Kodeš & Arnošt Mráz, 2011. "Comparison of two sensors ECH2O EC-5 and SM200 for measuring soil water content," Soil and Water Research, Czech Academy of Agricultural Sciences, vol. 6(2), pages 102-110.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:caa:jnlswr:v:3:y:2008:i:4:id:18-2008-swr. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Ivo Andrle (email available below). General contact details of provider: https://www.cazv.cz/en/home/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.