Abstract
In this paper, the design, simulation, fabrication and characterization of a prototype single fiber MRI compatible cascaded pressure sensor is presented. This paper represents the extended version of earlier communication on this topic. In addition to the earlier communication, in this paper, we report on a crucial design requirement: the immunity to Electro-Magnetic Interference (EMI). This immunity has been experimentally tested by combining the prototype sensors with a Siemens 1.5T Magnetic Resonance Imaging (MRI) apparatus at Haga Hospital (The Hague). No disturbance was observed during a full MRI imaging cycle. The system allows for long lasting usage in the range -50 mmHg to 300 mmHg without damage to the membrane. A static pressure resolution (averaged over the array) of 3.6 mmHg was found, a performance that needs improvement in the future. Simulations show that the desired resolution of 1.0 mmHg is feasible within this design approach. The dynamical response allows for registration of dynamical features up to 20 Hz, already meeting dynamical requirements of this low-cost sensing system and already exceeding expectations expressed in advance. Future work includes further miniaturization, catheter integration, improvement of static pressure resolution, tackling separation of temperature-pressure crosstalk by implementing alternating independent Fibre Bragg Grating (FBG) temperature sensors in the array and further enhancing dynamical properties.
Suggested Citation
L. Arntzen & M. van der Hoek & U. Wyder & D. Boesten & J. Schreuder & J. Bolte, 2026.
"Design and Performance Test of a Prototype MRI-Compatible Cascaded Pressure Microsensor,"
International Journal of Research and Innovation in Applied Science, International Journal of Research and Innovation in Applied Science (IJRIAS), vol. 11(3), pages 1091-1104, March.
Handle:
RePEc:bjf:journl:v:11:y:2026:i:3:p:1091-1104
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:bjf:journl:v:11:y:2026:i:3:p:1091-1104. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Dr. Renu Malsaria (email available below). General contact details of provider: https://rsisinternational.org/journals/ijrias/ .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.