Abstract

The accuracy, traceability, and reliability of calibration measurements is highly dependent on the environment in today's metrology laboratories. Ambient temperature, relative humidity, atmospheric pressure, vibration and airflow have significant impact on measurement uncertainty and on the long-term stability of calibrated instruments (JCGM 100:2008; Bell 2001). In this study, these environmental factors are evaluated using an advanced experimental and analytical methodology. Experiments were performed in controlled lab facilities with high accuracy balances, volumetric measuring glassware, and digital measurement system in the temperature range of 18 °C to 32 °C, relative humidity from 35% to 75% and under observed atmospheric pressure. The tests were repeated 10 times for each test condition (n=10), and 10 times for each instrument type for a total of 30 measurements per environmental condition (3 instruments × 10 repeats). Using the Guide to the Expression of Uncertainty in Measurement (JCGM 100:2008) relationships between environmental fluctuations and calibration deviations were quantified through statistical analysis and uncertainty modelling. The calibration uncertainty was largest for the volumetric measurement, 42%, and had a good linear dependence (R2 = 0.93) with temperature variation. For electronic instrumentation and mass measurements, the impacts of humidity were more pronounced, with the effect showing a non-linear relationship above 60% RH, which is consistent with Ahmed et al. (2019) and Wang et al. (2017). The overall calibration uncertainty was reduced by 18.7% (paired t-test, p

Suggested Citation

  • Mirola Afroze & Anila Pasha & Md Abu Hasan & Moktar Hossain, 2026. "Advanced Assessment of Environmental Factors Affecting Calibration Traceability and Measurement Reliability," International Journal of Research and Scientific Innovation, International Journal of Research and Scientific Innovation (IJRSI), vol. 13(5), pages 1437-1445, May.
  • Handle: RePEc:bjc:journl:v:13:y:2026:i:5:p:1437-1445
    as

    Download full text from publisher

    File URL: https://rsisinternational.org/journals/ijrsi/uploads/vol13-iss5-pg1437-1445-202606_pdf.pdf
    Download Restriction: no

    File URL: https://rsisinternational.org/journals/ijrsi/view/advanced-assessment-of-environmental-factors-affecting-calibration-traceability-and-measurement-reliability/
    Download Restriction: no
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:bjc:journl:v:13:y:2026:i:5:p:1437-1445. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Dr. Renu Malsaria (email available below). General contact details of provider: https://rsisinternational.org/journals/ijrsi/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.