IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v14y2022i3p1500-d736171.html
   My bibliography  Save this article

Assessment of PV Module Temperature Models for Building-Integrated Photovoltaics (BIPV)

Author

Listed:
  • Nuria Martín-Chivelet

    (CIEMAT-Photovoltaic Unit, Avda. Complutense 40, 28040 Madrid, Spain)

  • Jesús Polo

    (CIEMAT-Photovoltaic Unit, Avda. Complutense 40, 28040 Madrid, Spain)

  • Carlos Sanz-Saiz

    (CIEMAT-Photovoltaic Unit, Avda. Complutense 40, 28040 Madrid, Spain)

  • Lucy Tamara Núñez Benítez

    (UPM-Instituto de Energía Solar, Avda. Complutense 30, 28040 Madrid, Spain)

  • Miguel Alonso-Abella

    (CIEMAT-Photovoltaic Unit, Avda. Complutense 40, 28040 Madrid, Spain)

  • José Cuenca

    (CIEMAT-Photovoltaic Unit, Avda. Complutense 40, 28040 Madrid, Spain)

Abstract

This paper assesses two steady-state photovoltaic (PV) module temperature models when applied to building integrated photovoltaic (BIPV) rainscreens and curtain walls. The models are the Ross and the Faiman models, both extensively used for PV modules mounted on open-rack support structures in PV plants. The experimental setups arrange the BIPV modules vertically and with different backside boundary conditions to cover the mounting configurations under study. Data monitoring over more than a year was the experimental basis to assess each model by comparing simulated and measured temperatures with the help of four different metrics: mean absolute error, root mean square error, mean bias error, and coefficient of determination. The performance ratio of each system without the temperature effect was calculated by comparing the experimental energy output with the energy output determined with the measured temperatures. This parameter allowed the estimation of the PV energy with the predicted temperatures to assess the suitability of each temperature model for energy-prediction purposes. The assessment showed that the Ross model is the most suitable for predicting the annual PV energy in rainscreen and curtain-wall applications. Highlighted is the importance of fitting the model coefficients with a representative set of in situ monitored data. The data set should preferably include the inner (backside) temperature, i.e., the air chamber temperature in ventilated façades or the indoor temperature in curtain walls and windows.

Suggested Citation

  • Nuria Martín-Chivelet & Jesús Polo & Carlos Sanz-Saiz & Lucy Tamara Núñez Benítez & Miguel Alonso-Abella & José Cuenca, 2022. "Assessment of PV Module Temperature Models for Building-Integrated Photovoltaics (BIPV)," Sustainability, MDPI, vol. 14(3), pages 1-15, January.
  • Handle: RePEc:gam:jsusta:v:14:y:2022:i:3:p:1500-:d:736171
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/14/3/1500/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/14/3/1500/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Olivieri, L. & Caamaño-Martín, E. & Moralejo-Vázquez, F.J. & Martín-Chivelet, N. & Olivieri, F. & Neila-Gonzalez, F.J., 2014. "Energy saving potential of semi-transparent photovoltaic elements for building integration," Energy, Elsevier, vol. 76(C), pages 572-583.
    2. Lu, Lin & Law, Kin Man, 2013. "Overall energy performance of semi-transparent single-glazed photovoltaic (PV) window for a typical office in Hong Kong," Renewable Energy, Elsevier, vol. 49(C), pages 250-254.
    3. Miyazaki, T. & Akisawa, A. & Kashiwagi, T., 2005. "Energy savings of office buildings by the use of semi-transparent solar cells for windows," Renewable Energy, Elsevier, vol. 30(3), pages 281-304.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Krzysztof Barbusiński & Paweł Kwaśnicki & Anna Gronba-Chyła & Agnieszka Generowicz & Józef Ciuła & Bartosz Szeląg & Francesco Fatone & Agnieszka Makara & Zygmunt Kowalski, 2024. "Influence of Environmental Conditions on the Electrical Parameters of Side Connectors in Glass–Glass Photovoltaic Modules," Energies, MDPI, vol. 17(3), pages 1-13, January.
    2. Jesús Polo & Nuria Martín-Chivelet & Miguel Alonso-Abella & Carlos Sanz-Saiz & José Cuenca & Marina de la Cruz, 2023. "Exploring the PV Power Forecasting at Building Façades Using Gradient Boosting Methods," Energies, MDPI, vol. 16(3), pages 1-12, February.
    3. Yu Zheng & Xiaoming Li & Wenjie Zhang & Kuan Wang & Feng Han & Xiaoge Li & Yuqiang Zhao, 2022. "Experimental Study of Phase Change Microcapsule Suspensions Applied in BIPV Construction," Sustainability, MDPI, vol. 14(17), pages 1-14, August.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Tiantian Zhang & Meng Wang & Hongxing Yang, 2018. "A Review of the Energy Performance and Life-Cycle Assessment of Building-Integrated Photovoltaic (BIPV) Systems," Energies, MDPI, vol. 11(11), pages 1-34, November.
    2. Peng, Jinqing & Curcija, Dragan C. & Lu, Lin & Selkowitz, Stephen E. & Yang, Hongxing & Zhang, Weilong, 2016. "Numerical investigation of the energy saving potential of a semi-transparent photovoltaic double-skin facade in a cool-summer Mediterranean climate," Applied Energy, Elsevier, vol. 165(C), pages 345-356.
    3. Yu, Guoqing & Yang, Hongxing & Luo, Daina & Cheng, Xu & Ansah, Mark Kyeredey, 2021. "A review on developments and researches of building integrated photovoltaic (BIPV) windows and shading blinds," Renewable and Sustainable Energy Reviews, Elsevier, vol. 149(C).
    4. Joaquim Romaní & Alba Ramos & Jaume Salom, 2022. "Review of Transparent and Semi-Transparent Building-Integrated Photovoltaics for Fenestration Application Modeling in Building Simulations," Energies, MDPI, vol. 15(9), pages 1-30, April.
    5. Yang, Tingting & Athienitis, Andreas K., 2016. "A review of research and developments of building-integrated photovoltaic/thermal (BIPV/T) systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 66(C), pages 886-912.
    6. Wang, Chuyao & Ji, Jie & Uddin, Md Muin & Yu, Bendong & Song, Zhiying, 2021. "The study of a double-skin ventilated window integrated with CdTe cells in a rural building," Energy, Elsevier, vol. 215(PA).
    7. Olivieri, L. & Caamaño-Martín, E. & Moralejo-Vázquez, F.J. & Martín-Chivelet, N. & Olivieri, F. & Neila-Gonzalez, F.J., 2014. "Energy saving potential of semi-transparent photovoltaic elements for building integration," Energy, Elsevier, vol. 76(C), pages 572-583.
    8. Xuan, Qingdong & Li, Guiqiang & Lu, Yashun & Zhao, Bin & Wang, Fuqiang & Pei, Gang, 2021. "Daylighting utilization and uniformity comparison for a concentrator-photovoltaic window in energy saving application on the building," Energy, Elsevier, vol. 214(C).
    9. Wu, Zhenghong & Zhang, Ling & Su, Xiaosong & Wu, Jing & Liu, Zhongbing, 2022. "Experimental and numerical analysis of naturally ventilated PV-DSF in a humid subtropical climate," Renewable Energy, Elsevier, vol. 200(C), pages 633-646.
    10. Cheng, Yuanda & Gao, Min & Jia, Jie & Sun, Yanyi & Fan, Yi & Yu, Min, 2019. "An optimal and comparison study on daylight and overall energy performance of double-glazed photovoltaics windows in cold region of China," Energy, Elsevier, vol. 170(C), pages 356-366.
    11. Uddin, Md Muin & Wang, Chuyao & Zhang, Chengyan & Ji, Jie, 2022. "Investigating the energy-saving performance of a CdTe-based semi-transparent photovoltaic combined hybrid vacuum glazing window system," Energy, Elsevier, vol. 253(C).
    12. Vassiliades, Constantinos & Michael, Aimilios & Savvides, Andreas & Kalogirou, Soteris, 2018. "Improvement of passive behaviour of existing buildings through the integration of active solar energy systems," Energy, Elsevier, vol. 163(C), pages 1178-1192.
    13. Abdelhakim Mesloub & Ghazy Abdullah Albaqawy & Mohd Zin Kandar, 2020. "The Optimum Performance of Building Integrated Photovoltaic (BIPV) Windows Under a Semi-Arid Climate in Algerian Office Buildings," Sustainability, MDPI, vol. 12(4), pages 1-38, February.
    14. Sun, Yanyi & Shanks, Katie & Baig, Hasan & Zhang, Wei & Hao, Xia & Li, Yongxue & He, Bo & Wilson, Robin & Liu, Hao & Sundaram, Senthilarasu & Zhang, Jingquan & Xie, Lingzhi & Mallick, Tapas & Wu, Yupe, 2018. "Integrated semi-transparent cadmium telluride photovoltaic glazing into windows: Energy and daylight performance for different architecture designs," Applied Energy, Elsevier, vol. 231(C), pages 972-984.
    15. Refat, Khalid H. & Sajjad, Redwan N., 2020. "Prospect of achieving net-zero energy building with semi-transparent photovoltaics: A device to system level perspective," Applied Energy, Elsevier, vol. 279(C).
    16. Li, Xian & Lin, Alexander & Young, Chin-Huai & Dai, Yanjun & Wang, Chi-Hwa, 2019. "Energetic and economic evaluation of hybrid solar energy systems in a residential net-zero energy building," Applied Energy, Elsevier, vol. 254(C).
    17. Chen, Mo & Zhang, Wei & Xie, Lingzhi & Ni, Zhichun & Wei, Qingzhu & Wang, Wei & Tian, Hao, 2019. "Experimental and numerical evaluation of the crystalline silicon PV window under the climatic conditions in southwest China," Energy, Elsevier, vol. 183(C), pages 584-598.
    18. Skandalos, Nikolaos & Karamanis, Dimitris, 2015. "PV glazing technologies," Renewable and Sustainable Energy Reviews, Elsevier, vol. 49(C), pages 306-322.
    19. Hee, W.J. & Alghoul, M.A. & Bakhtyar, B. & Elayeb, OmKalthum & Shameri, M.A. & Alrubaih, M.S. & Sopian, K., 2015. "The role of window glazing on daylighting and energy saving in buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 42(C), pages 323-343.
    20. Peng, Jinqing & Curcija, Dragan C. & Thanachareonkit, Anothai & Lee, Eleanor S. & Goudey, Howdy & Selkowitz, Stephen E., 2019. "Study on the overall energy performance of a novel c-Si based semitransparent solar photovoltaic window," Applied Energy, Elsevier, vol. 242(C), pages 854-872.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:14:y:2022:i:3:p:1500-:d:736171. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.