Author
Listed:
- Harsha Varthini P.B.
- Yasoda K.
Abstract
Significant equipment like electric arc furnaces (EAFs) and ladle refining furnaces (LRFs) are among the highly dynamic and nonlinear electrical loads found in steel production facilities like Surana Industry. Reactive power imbalance, harmonic distortion, and voltage instability are just a few of the significant power quality issues caused by these complex loads. Because of this, accurate modeling and thorough analysis of these complex power systems are essential to ensuring operational dependability and maintaining power quality. The current literature tends to emphasize mostly steady-state conditions that are frequently not verified empirically with respect to actual operating data, despite the fact that the Electrical Transient Analyzer Program (ETAP) is a common tool used for load flow analysis in industry applications. With an emphasis on accurately simulating the real system behavior under various operating regimes, this paper provides a thorough power flow analysis of the Surana Steel Industry using ETAP. Two 100 MVA, 220/110 kV transformers step down the 110 kV supply that powers the plant, which is drawn from the Chikkasagur substation. The primary loads—a 35-ton rolling mill, a 4 MW EAF, and an LRF are supplemented with a captive power generation system and a harmonic filter to improve power quality and reliability. Under five different operating conditions with different load levels and generator configurations, key performance metrics such as voltage regulation, reactive power flow, harmonic suppression, and generator dynamic response are thoroughly assessed. The power system of the Surana Steel Industry is accurately simulated by the analytical method employed here. Even though a real-time comparison with SCADA data was not attempted, the ETAP model was painstakingly built with detailed equipment specs, typical operating conditions, and performance patterns actually observed at the facility. Accurate simulation of industrial environments, including the complex, unbalanced, and nonlinear loads present in steel mills, was made possible by this all-encompassing approach. Thus, this study shows that when appropriately configured and backed by extensive empirical data, ETAP has a considerable ability to accurately model these difficult environments. These results offer practical information that can be used right away for large-scale industrial power system planning, assessment, and enhancement.
Suggested Citation
Handle:
RePEc:gvu:iroei0:v:7:y:2025:i:2:id:583
DOI: 10.36548/jei.2025.2.006
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gvu:iroei0:v:7:y:2025:i:2:id:583. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Journal Manager (email available below). General contact details of provider: https://irojournals.com/iroei .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.