Author
Abstract
Fault detection in the transmission is a challenging task when examining the accuracy of the system. This fault can be caused by a man-made force or by using concurrent overvoltage in the power distribution line. This research focuses on two sections to handle the power transmission line problem and can be rectified as previously stated. An intelligent approach is utilized for monitoring and controlling line faults in order to improve the accuracy of the equipment in transmission line fault detection. After several iterations of the procedure, the combination of line and master unit improves the system's accuracy and reliability. The master unit identifies faulty poles in the network based on the variation of current and voltage of each node and calculates the distance between the station and the faulty node to reduce manual effort. In the proposed work, many sensors are used to detect the line fault in a network by placing the appropriate point. The pure information can be transferred to an authorized person or unit after many iterations due to knowledgeable devices. The faulty status of the pole information is displayed in the control unit by a display unit comprised of an alarm unit to alert the corresponding section using ZigBee techniques. The GSM unit provides the faulty status of an authorized person to rectify the problems immediately which further improve the reliability of the system. When compared to existing methods, our hybrid proposed method achieves a higher accuracy of 90%. This method aids to reduce the labor costs gradually to visit all-pole points instead of faulty pole points and thereby increasing the reliability of the electrical consumers.
Suggested Citation
Handle:
RePEc:gvu:iroei0:v:3:y:2021:i:1:id:458
DOI: 10.36548/jei.2021.1.004
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gvu:iroei0:v:3:y:2021:i:1:id:458. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Journal Manager (email available below). General contact details of provider: https://irojournals.com/iroei .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.