IDEAS home Printed from https://ideas.repec.org/a/gvu/iroeea/v8y2026i4id2446.html

Design and Evaluation of an Additively Manufactured Smart Infusion Pump with Embedded Control and Pressure-based Safety Monitoring

Author

Listed:
  • Murugan A.
  • Sheela M.
  • Tarunika B.
  • Vinothini K.

Abstract

This research introduces the design and laboratory testing of a smart infusion pump prototype using the principles of additive manufacturing, embedded controller, sensor-based safety monitoring, and wireless communication. Mechanical design utilizes a syringe-based actuator driven by a stepper motor that was fabricated via the process of additive manufacturing to ensure a precise displacement of the plunger, whereas ESP8266-based controller ensures control over actuator actuation, user interface, pressure monitoring, and fault handling. Prototype testing was performed in a laboratory environment using water at present flow rates of 5, 10, 20, 30, and 40 mL/h. Observed delivery rates were 5.1, 9.8, 19.6, 29.4, and 39.2 mL/h, respectively, implying that maximum error was ±2%. Repeated-cycles operation proved mechanical integrity of the prototype without any signs of deformations or misalignments. The developed integrated safety response system Occlusion detection based on pressure measurement, end-of-travel detection, motor stoppage, and alarm triggering.

Suggested Citation

Handle: RePEc:gvu:iroeea:v:8:y:2026:i:4:id:2446
DOI: 10.36548/jeea.2026.4.001
as

Download full text from publisher

File URL: https://irojournals.com/iroeea/article/view/2446
File Function: Abstract page
Download Restriction: no

File URL: https://irojournals.com/iroeea/article/download/2446/2251
File Function: Full text
Download Restriction: no

File URL: https://libkey.io/10.36548/jeea.2026.4.001?utm_source=ideas
LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
---><---

More about this item

Keywords

;
;
;
;
;
;
;

JEL classification:

Statistics

Access and download statistics

Corrections

All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gvu:iroeea:v:8:y:2026:i:4:id:2446. See general information about how to correct material in RePEc.

If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

We have no bibliographic references for this item. You can help adding them by using this form .

If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Journal Manager (email available below). General contact details of provider: https://irojournals.com/iroeea .

Please note that corrections may take a couple of weeks to filter through the various RePEc services.

IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.