Abstract
Beam quality verification is a fundamental aspect of radiotherapy commissioning and quality assurance, ensuring that photon beams from medical linear accelerators correspond to their nominal energies and comply with international dosimetry protocols. For megavoltage beams, indices such as percentage depth dose (PDD) at 10cm, tissue phantom ratio at depths of 10cm and 20cm (TPR20,10 ), and quality conversion factor kQ, Q0, are used to characterize beam quality. Accurate measurement of these parameters is essential to achieving consistent dose delivery and maintaining patient safety. This study aims to determine and verify the beam quality of 6MV and 10MV photon beams from Elekta Synergy linear accelerator for treatment plan quality assurance. Beam quality measurements were performed in water in a 3D water phantom at 100cm source-to-chamber distance (SCD) of 100cm and a field size of 10cm x 10cm at the chamber plane. A calibrated cylindrical Farmer type ionization chamber (30010) connected to a calibrated PTW UNIDOS electrometer (60731) was used to obtain depth-dose readings, the kQ, Q0 value were then evaluated using the IAEA TRS 398 TPR20,10 method. Measurements were taken at depths of 20cm and 10cm beneath the water surface, and at three different polarities of +300, +150, and -300 polarities on the electrometer. For the 6MV photon beam, the kQ, Q0 value was 0.993, TPR20,10 was 0.67, PDD(10) was 66.38% and the absorbed dose to water at Zmax was 0.9941cGy/MU and for the 10MV photon energy, the kQ, Q0 value was 0.983, TPR20,10 was 0.73, the PDD was 74.8% and the absorbed dose to water at Zmax was 1.004cGy/MU, these values are consistent with international reference standards. Beam quality verification confirmed that the Elekta Synergy linear accelerator delivers accurate 6MV and 10MV photon beams in compliance with TG-51 and IAEA TRS-398. Routine quality checks remain essential to ensure precise dose delivery and optimize radiotherapy outcomes.
Suggested Citation
Handle:
RePEc:cxi:ijans0:v:3:y:2025:i:3:id:551
DOI: 10.61424/ijans.v3i3.551
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:cxi:ijans0:v:3:y:2025:i:3:id:551. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Editorial Team (email available below). General contact details of provider: https://bluemarkpublishers.com/index.php/IJANS .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.