IDEAS home Printed from https://ideas.repec.org/a/wsi/srlxxx/v23y2016i05ns0218625x16500451.html
   My bibliography  Save this article

Study Of Nickel Ion Release In Simulated Body Fluid From C+-Implanted Nickel Titanium Alloy

Author

Listed:
  • MUHAMMAD AHSAN SHAFIQUE

    (Centre for Advanced Studies in Physics, GC University, Lahore, Pakistan†Department of Physics, GC University, Lahore, Pakistan)

  • G. MURTAZA

    (Centre for Advanced Studies in Physics, GC University, Lahore, Pakistan)

  • SHAHZAD SAADAT

    (Centre for Advanced Studies in Physics, GC University, Lahore, Pakistan)

  • ZEESHAN ZAHEER

    (Centre for Advanced Studies in Physics, GC University, Lahore, Pakistan)

  • MUHAMMAD SHAHNAWAZ

    (Centre for Advanced Studies in Physics, GC University, Lahore, Pakistan)

  • MUHAMMAD K. H. UDDIN

    (#x2021;Department of Materials Science and Engineering, Kroto Research Institute, University of Sheffield, Sheffield S3 7HQ, UK)

  • RIAZ AHMAD

    (Centre for Advanced Studies in Physics, GC University, Lahore, Pakistan)

Abstract

Nickel ion release from NiTi shape memory alloy is an issue for biomedical applications. This study was planned to study the effect of C+ implantation on nickel ion release and affinity of calcium phosphate precipitation on NiTi alloy. Four annealed samples are chosen for the present study; three samples with oxidation layer and the fourth without oxidation layer. X-ray diffraction (XRD) spectra reveal amorphization with ion implantation. Proton-induced X-ray emission (PIXE) result shows insignificant increase in Ni release in simulated body fluid (SBF) and calcium phosphate precipitation up to 8×1013ions/cm2. Then Nickel contents show a sharp increase for greater ion doses. Corrosion potential decreases by increasing the dose but all the samples passivate after the same interval of time and at the same level of VSCE in ringer lactate solution. Hardness of samples initially increases at greater rate (up to 8×1013ions/cm2) and then increases with lesser rate. It is found that 8×1013ions/cm2 (≈1014) is a safer limit of implantation on NiTi alloy, this limit gives us lesser ion release, better hardness and reasonable hydroxyapatite incubation affinity.

Suggested Citation

  • Muhammad Ahsan Shafique & G. Murtaza & Shahzad Saadat & Zeeshan Zaheer & Muhammad Shahnawaz & Muhammad K. H. Uddin & Riaz Ahmad, 2016. "Study Of Nickel Ion Release In Simulated Body Fluid From C+-Implanted Nickel Titanium Alloy," Surface Review and Letters (SRL), World Scientific Publishing Co. Pte. Ltd., vol. 23(05), pages 1-6, October.
  • Handle: RePEc:wsi:srlxxx:v:23:y:2016:i:05:n:s0218625x16500451
    DOI: 10.1142/S0218625X16500451
    as

    Download full text from publisher

    File URL: http://www.worldscientific.com/doi/abs/10.1142/S0218625X16500451
    Download Restriction: Access to full text is restricted to subscribers

    File URL: https://libkey.io/10.1142/S0218625X16500451?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:wsi:srlxxx:v:23:y:2016:i:05:n:s0218625x16500451. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Tai Tone Lim (email available below). General contact details of provider: http://www.worldscinet.com/srl/srl.shtml .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.