IDEAS home Printed from https://ideas.repec.org/a/wly/jocnur/v27y2018i3-4p677-683.html
   My bibliography  Save this article

Factors which influence concordance among measurements obtained by different pulse oximeters currently used in some clinical situations

Author

Listed:
  • Candelaria de la Merced Díaz‐González
  • Milagros de la Rosa‐Hormiga
  • Josefa M. Ramal‐López
  • Juan José González‐Henríquez
  • María Sandra Marrero‐Morales

Abstract

Aims and objectives To evaluate both concordance among those measurements obtained by three different pulse oximeters currently used by nursing professionals in hospital units and the factors which can influence this concordance. Background Many models of wireless pulse oximeters in the present market do not offer possibility of calibration and, therefore, they do not ensure patients′ safety in daily clinical practice. Design This is a descriptive and cross‐sectional study. The sample of patients (140) was selected from such hospital units, and all of them had to fulfil inclusion and exclusion criteria for participation. Methods The instruments used to carry out this research were a monitor (calibrated), two models of portable wireless pulse oximeters (used for 3 years by the nursing staff, without being calibrated), a tympanic thermometer and a weather meter. The concordance correlation coefficient (CCC) was used to establish the concordance, whereas the Landis‐Koch criteria were used to interpret the results. Results The concordance among the three devices was considered as “good” (CCC: 0.925 and 0.974 (95%)). The CCC (0.925) for saturation measures was regarded as “very good”/”almost perfect,” and the pulse measure was considered as “very good” CCC 0.974, providing in both cases a high level of concordance (CCC > 0.91). Conclusions The overall concordance as regards pulse and oxygen saturation among the three pulse oximeters analysed is considered as “very good” according to the Landis‐Koch criteria. Relevance to clinical practice There exists a “very good” concordance among two wireless oximeters which have been used by the health staff for 3 years and which did not offer any possibility of calibration and one monitor which belongs to the healthcare institution. This aspect is of crucial importance in daily clinical practice, and it is also relevant to ensure patient's safety.

Suggested Citation

  • Candelaria de la Merced Díaz‐González & Milagros de la Rosa‐Hormiga & Josefa M. Ramal‐López & Juan José González‐Henríquez & María Sandra Marrero‐Morales, 2018. "Factors which influence concordance among measurements obtained by different pulse oximeters currently used in some clinical situations," Journal of Clinical Nursing, John Wiley & Sons, vol. 27(3-4), pages 677-683, February.
  • Handle: RePEc:wly:jocnur:v:27:y:2018:i:3-4:p:677-683
    DOI: 10.1111/jocn.14012
    as

    Download full text from publisher

    File URL: https://doi.org/10.1111/jocn.14012
    Download Restriction: no

    File URL: https://libkey.io/10.1111/jocn.14012?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    References listed on IDEAS

    as
    1. Chen, Chia-Cheng & Barnhart, Huiman X., 2008. "Comparison of ICC and CCC for assessing agreement for data without and with replications," Computational Statistics & Data Analysis, Elsevier, vol. 53(2), pages 554-564, December.
    2. Huiman X. Barnhart & Michael Haber & Jingli Song, 2002. "Overall Concordance Correlation Coefficient for Evaluating Agreement Among Multiple Observers," Biometrics, The International Biometric Society, vol. 58(4), pages 1020-1027, December.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Helenowski Irene B & Vonesh Edward F & Demirtas Hakan & Rademaker Alfred W & Ananthanarayanan Vijayalakshmi & Gann Peter H & Jovanovic Borko D, 2011. "Defining Reproducibility Statistics as a Function of the Spatial Covariance Structures in Biomarker Studies," The International Journal of Biostatistics, De Gruyter, vol. 7(1), pages 1-21, January.
    2. Ying Guo & Amita K. Manatunga, 2007. "Nonparametric Estimation of the Concordance Correlation Coefficient under Univariate Censoring," Biometrics, The International Biometric Society, vol. 63(1), pages 164-172, March.
    3. Matheus Pereira Libório & Lívia Maria Leite Silva & Petr Iakovlevitch Ekel & Letícia Ribeiro Figueiredo & Patrícia Bernardes, 2022. "Consensus-Based Sub-Indicator Weighting Approach: Constructing Composite Indicators Compatible with Expert Opinion," Social Indicators Research: An International and Interdisciplinary Journal for Quality-of-Life Measurement, Springer, vol. 164(3), pages 1073-1099, December.
    4. Chen, Chia-Cheng & Barnhart, Huiman X., 2013. "Assessing agreement with intraclass correlation coefficient and concordance correlation coefficient for data with repeated measures," Computational Statistics & Data Analysis, Elsevier, vol. 60(C), pages 132-145.
    5. Admassu N. Lamu, 2020. "Does linear equating improve prediction in mapping? Crosswalking MacNew onto EQ-5D-5L value sets," The European Journal of Health Economics, Springer;Deutsche Gesellschaft für Gesundheitsökonomie (DGGÖ), vol. 21(6), pages 903-915, August.
    6. John J. Chen & Guangxiang Zhang & Chen Ji & George F. Steinhardt, 2011. "Simple moment-based inferences of generalized concordance correlation," Journal of Applied Statistics, Taylor & Francis Journals, vol. 38(9), pages 1867-1882, October.
    7. Yan Ma & Wan Tang & Changyong Feng & Xin M. Tu, 2008. "Inference for Kappas for Longitudinal Study Data: Applications to Sexual Health Research," Biometrics, The International Biometric Society, vol. 64(3), pages 781-789, September.
    8. Tsai, Miao-Yu, 2015. "Comparison of concordance correlation coefficient via variance components, generalized estimating equations and weighted approaches with model selection," Computational Statistics & Data Analysis, Elsevier, vol. 82(C), pages 47-58.
    9. Chen, Chia-Cheng & Barnhart, Huiman X., 2008. "Comparison of ICC and CCC for assessing agreement for data without and with replications," Computational Statistics & Data Analysis, Elsevier, vol. 53(2), pages 554-564, December.
    10. Tsai, Miao-Yu & Lin, Chao-Chun, 2018. "Concordance correlation coefficients estimated by variance components for longitudinal normal and Poisson data," Computational Statistics & Data Analysis, Elsevier, vol. 121(C), pages 57-70.
    11. Gao, Jingjing & Pan, Yi & Haber, Michael, 2012. "Assessment of observer agreement for matched repeated binary measurements," Computational Statistics & Data Analysis, Elsevier, vol. 56(5), pages 1052-1060.
    12. Dennis Mackin & Xenia Fave & Lifei Zhang & Jinzhong Yang & A Kyle Jones & Chaan S Ng & Laurence Court, 2017. "Harmonizing the pixel size in retrospective computed tomography radiomics studies," PLOS ONE, Public Library of Science, vol. 12(9), pages 1-17, September.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:wly:jocnur:v:27:y:2018:i:3-4:p:677-683. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Wiley Content Delivery (email available below). General contact details of provider: https://doi.org/10.1111/(ISSN)1365-2702 .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.