IDEAS home Printed from https://ideas.repec.org/a/taf/gcmbxx/v19y2016i1p49-59.html
   My bibliography  Save this article

Pseudo-dynamic analysis of a cemented hip arthroplasty using a force method based on the Newmark algorithm

Author

Listed:
  • A. Ramos
  • P. Talaia
  • F.J. Queirós de Melo

Abstract

The main goal of this work was to develop an approached model to study dynamic behavior and prediction of the stress distribution in an in vitro Charnley cemented hip arthroplasty. An alternative version of the described pseudo-dynamic procedure is proposed by using the time integration Newmark algorithm. An internal restoring force vector is numerically calculated from the displacement, velocity, and acceleration vectors. A numerical model of hip replacement was developed to analyze the deformation of a dynamically stressed structure for all time steps. The experimental measurement of resulting internal forces generated in the structure (internal restoring force vector) is the second fundamental step of the pseudo-dynamic procedure. These data (as a feedback) are used by the time integration algorithm, which allows updating of the structure's shape for the next displacement, velocity, and acceleration vectors. In the field of Biomechanics, the potentialities of this method contribute to the determination of a dynamically equivalent in vitro stress field of a cemented hip prosthesis; implant fitted in patients with a normal mobility or practice sports. Consequences of the stress distribution in the implant zone that underwent cyclic fatigue loads were also discussed by using a finite element model. Application of this method in Biomechanics appears as a useful tool in the approximate stress field characterization of the peak stress state. Results show a peak value around two times the static situation, more for making possible the prediction of future damage and a programed clinical examination in patients using hip prosthesis.

Suggested Citation

  • A. Ramos & P. Talaia & F.J. Queirós de Melo, 2016. "Pseudo-dynamic analysis of a cemented hip arthroplasty using a force method based on the Newmark algorithm," Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 19(1), pages 49-59, January.
  • Handle: RePEc:taf:gcmbxx:v:19:y:2016:i:1:p:49-59
    DOI: 10.1080/10255842.2014.983491
    as

    Download full text from publisher

    File URL: http://hdl.handle.net/10.1080/10255842.2014.983491
    Download Restriction: Access to full text is restricted to subscribers.

    File URL: https://libkey.io/10.1080/10255842.2014.983491?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:19:y:2016:i:1:p:49-59. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.