IDEAS home Printed from https://ideas.repec.org/a/taf/gcmbxx/v18y2015i2p153-161.html
   My bibliography  Save this article

Improving stability of locking compression plates through a design modification: a computational investigation

Author

Listed:
  • D. Anitha
  • Shamal Das De
  • Khong Kok Sun
  • Hitendra K. Doshi
  • Taeyong Lee

Abstract

Femoral shaft fractures are common in both the young and elderly due to high-impact trauma and low-impact trauma, respectively. Its treatment by indirect reduction through use of locking compression plates (LCPs) has been on the rise. The LCP possess several advantages in fracture fixation, combining angular stability through use of locking screws with misalignment correction and fracture reduction onto the plate through use of conventional screws. However, there have been cases of plate breakage and fracture non-unions to warrant a study to improve its stability. A design modification is suggested for mid-diaphyseal fractures, whereby unused screw holes are removed. The structural stability of the modified and commercially available LCP is computationally analyzed using finite element modelling and a comparison made in terms of mechanical performance across different fracture lengths. A critical fracture length for which the commercially available LCP is functional as a fixator for mid-diaphyseal fractures was established. The maximum von Mises' stress attained by the commercially available LCP rose to as high as 105 MPa, whereas for the modified LCP, it did not exceed 25 MPa. As expected, these stresses were also found at screw holes, nearest to the fracture site. Critical fracture length allows clinicians to quantitatively distinguish between mid-diaphyseal fractures that can or cannot be treated by the use of LCP fixation. It is also believed that the proposed design modification will substantially increase the fatigue life of the fixator, especially at screw holes nearest to the fracture region, where most fatigue fractures are known to occur and will consequently be functional for greater fracture lengths.

Suggested Citation

  • D. Anitha & Shamal Das De & Khong Kok Sun & Hitendra K. Doshi & Taeyong Lee, 2015. "Improving stability of locking compression plates through a design modification: a computational investigation," Computer Methods in Biomechanics and Biomedical Engineering, Taylor & Francis Journals, vol. 18(2), pages 153-161, January.
  • Handle: RePEc:taf:gcmbxx:v:18:y:2015:i:2:p:153-161
    DOI: 10.1080/10255842.2013.785536
    as

    Download full text from publisher

    File URL: http://hdl.handle.net/10.1080/10255842.2013.785536
    Download Restriction: Access to full text is restricted to subscribers.

    File URL: https://libkey.io/10.1080/10255842.2013.785536?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:taf:gcmbxx:v:18:y:2015:i:2:p:153-161. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Chris Longhurst (email available below). General contact details of provider: http://www.tandfonline.com/gcmb .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.