IDEAS home Printed from https://ideas.repec.org/a/plo/pone00/0186453.html
   My bibliography  Save this article

Correlations between local peripapillary choroidal thickness and axial length, optic disc tilt, and papillo-macular position in young healthy eyes

Author

Listed:
  • Takehiro Yamashita
  • Taiji Sakamoto
  • Naoya Yoshihara
  • Hiroto Terasaki
  • Minoru Tanaka
  • Yuya Kii
  • Kumiko Nakao

Abstract

Optical coherence tomography (OCT) has made it possible for clinicians to measure the peripapillary choroidal thickness (ppCT) noninvasively in various ocular diseases. However, the ocular factors associated with the ppCT have not been conclusively determined. The purpose of this study was to determine the relationship between the local ppCT and the axial length, optic disc tilt, and the angle of the papillo-macular position (PMP) in healthy eyes. This was a prospective, observational cross-sectional study of 119 right eyes of 119 healthy Japanese volunteers. The ppCT was manually measured at eight sectors around the optic disc using the B-scan images of the Topcon 3D OCT RNFL 3.4 mm circle scan. The trajectory of the retinal pigment epithelium in the B-scan image was fitted to a sine curve using ImageJ, and the amplitude of the sine curve was used to determine the degree of the optic disc tilt. The PMP angle was determined in the color fundus photographs. The relationships between the ppCT and the axial length, the optic disc tilt, and PMP angle were determined by Spearman and multiple correlation analyses. The mean age was 25.8 ± 3.9 years and the mean axial length was 25.5 ± 1.4 mm. The ppCT was significantly and negatively associated with the axial length (R = -0.43 to -0.24, P

Suggested Citation

  • Takehiro Yamashita & Taiji Sakamoto & Naoya Yoshihara & Hiroto Terasaki & Minoru Tanaka & Yuya Kii & Kumiko Nakao, 2017. "Correlations between local peripapillary choroidal thickness and axial length, optic disc tilt, and papillo-macular position in young healthy eyes," PLOS ONE, Public Library of Science, vol. 12(10), pages 1-11, October.
  • Handle: RePEc:plo:pone00:0186453
    DOI: 10.1371/journal.pone.0186453
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0186453
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0186453&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0186453?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    References listed on IDEAS

    as
    1. Hiroto Terasaki & Takehiro Yamashita & Naoya Yoshihara & Yuya Kii & Minoru Tanaka & Kumiko Nakao & Taiji Sakamoto, 2016. "Location of Tessellations in Ocular Fundus and Their Associations with Optic Disc Tilt, Optic Disc Area, and Axial Length in Young Healthy Eyes," PLOS ONE, Public Library of Science, vol. 11(6), pages 1-8, June.
    2. Takehiro Yamashita & Taiji Sakamoto & Naoya Yoshihara & Hiroto Terasaki & Yuya Kii & Minoru Tanaka & Kumiko Nakao, 2015. "Circumpapillary Course of Retinal Pigment Epithelium Can Be Fit to Sine Wave and Amplitude of Sine Wave Is Significantly Correlated with Ovality Ratio of Optic Disc," PLOS ONE, Public Library of Science, vol. 10(4), pages 1-10, April.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Hiroto Terasaki & Takehiro Yamashita & Naoya Yoshihara & Yuya Kii & Minoru Tanaka & Kumiko Nakao & Taiji Sakamoto, 2016. "Location of Tessellations in Ocular Fundus and Their Associations with Optic Disc Tilt, Optic Disc Area, and Axial Length in Young Healthy Eyes," PLOS ONE, Public Library of Science, vol. 11(6), pages 1-8, June.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0186453. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.