IDEAS home Printed from https://ideas.repec.org/a/plo/pone00/0128146.html
   My bibliography  Save this article

iStent as a Solo Procedure for Glaucoma Patients: A Systematic Review and Meta-Analysis

Author

Listed:
  • Monali S Malvankar-Mehta
  • Yufeng Nancy Chen
  • Yiannis Iordanous
  • Wan Wendy Wang
  • John Costella
  • Cindy M L Hutnik

Abstract

Background: Glaucoma is a leading cause of irreversible blindness. It is firmly entrenched in the traditional treatment paradigm to start with pharmacotherapy. However, pharmacotherapy is not benign and has been well documented to have a number of significant challenges. Minimally invasive glaucoma surgery (MIGS) that targets the outflow pathway with minimal to no scleral dissection has resulted in the need to reconsider the glaucoma treatment paradigm. Purpose: To perform a systematic review and meta-analysis to evaluate and quantify the effect on post-operative intraocular pressure (IOP) and number of topical glaucoma medications, in patients receiving the iStent MIGS device as the solo procedure without concurrent cataract surgery. Methods: A systematic review was conducted by searching various databases between January 1, 2000, and June 30, 2014. Studies reporting up to a maximum follow-up period of 24 months were retrieved and screened using the EPPI-Reviewer 4 gateway. Percentage reduction in IOP (IOPR%), and mean reduction in topical glaucoma medications after surgery were computed. Meta-analysis was performed using STATA v. 13.0. The standardized mean difference (SMD) was calculated as the effect size for continuous scale outcomes. Heterogeneity was determined using the I2 statistics, Z-value, and χ2 statistics. Fixed-effect and random-effect models were developed based on heterogeneity. Sub-group analysis was performed based on the number of iStents implanted and the follow-up period. The outcome measures were changes in the IOP and number of glaucoma medications. Results: The search strategy identified 105 records from published literature and 9 records from the grey literature. Five studies with 248 subjects were included for quantitative synthesis. A 22% IOP reduction (IOPR%) from baseline occurred at 18-months after one iStent implant, 30% at 6-months after two iStents implantations, and 40% at 6-months after implantation of three iStents. A mean reduction of 1.2 bottles per patient of topical glaucoma medications occurred at 18-months after one iStent implant, 1.45 bottles per patient at 6-months after two iStents, and one bottle of medication per patient was reduced at 6-months following placement of three iStents implants. Meta-analysis results showed a significant reduction in the IOP after one iStent (SMD = -1.68, 95% CI: [-2.7, -0.61]), two iStents (SMD = -1.88, 95% CI: [-2.2, -1.56]), and three iStents (SMD = -2, 95% CI: [-2.62, -1.38]) implantation. Results showed a significant drop in the topical glaucoma medications after one iStent (SMD = -2.11, CI: [-3.95, -0.27]), two iStent (SMD = -1.88, CI: [-2.20, -1.56]), and three iStents (SMD = -2.00, CI: [-2.62, -1.38]) implantation. The maximum reduction in IOP occurred at 12-months (SMD = -2.21, CI: [-2.53, -1.88]) and a significant reduction in post-operative topical glaucoma medications occurred even after 18-months of iStent implantation (SMD = -0.71, CI: [-1.15, -0.26]). Conclusion: iStent implantation as a solo procedure without concurrent cataract extraction does lower IOP, and reduces the dependency on glaucoma medications. This effect seems to last at least 18 months.

Suggested Citation

  • Monali S Malvankar-Mehta & Yufeng Nancy Chen & Yiannis Iordanous & Wan Wendy Wang & John Costella & Cindy M L Hutnik, 2015. "iStent as a Solo Procedure for Glaucoma Patients: A Systematic Review and Meta-Analysis," PLOS ONE, Public Library of Science, vol. 10(5), pages 1-19, May.
  • Handle: RePEc:plo:pone00:0128146
    DOI: 10.1371/journal.pone.0128146
    as

    Download full text from publisher

    File URL: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0128146
    Download Restriction: no

    File URL: https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0128146&type=printable
    Download Restriction: no

    File URL: https://libkey.io/10.1371/journal.pone.0128146?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:plo:pone00:0128146. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: plosone (email available below). General contact details of provider: https://journals.plos.org/plosone/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.