Abstract

Composite construction with traditional Hot Rolled Steel (HRS) sections has been known to perform much better than with Cold-Formed Steel (CFS) sections for decades; as observed by extensive rules and requirements for their design as prescribed in current design codes. There is, however, limited technical information available about the use of composite systems that incorporates the use of light gauge steel sections, despite the potentials of the system in residential and light industrial constructions. However, the composite action of CFS with an in-situ concrete, especially Self-Compacting Concrete (SCC) using bolted shear connector has not yet established. Therefore, this study attempted to investigate the behaviour of bolted shear connector used with SCC and CFS to form a composite beam system at designated longitudinal spacing. Push-out and full-scale test specimens of longitudinal spacing of 250 mm and 300 mm with bolted shear connector of grade 8.8 installed with single nut and washer on the CFS flange and beneath it were fabricated, cast and tested till failure occurred. The experimental test results shows that the bolted shear connector possessed good ultimate strength and ultimate moment capacities with an increase in the longitudinal spacing of the bolted shear connector from 250 mm and to 300 mm respectively. It was therefore concluded that, longitudinal spacing between bolted shear connectors had significantly influenced the shear connector strength capacities.

Suggested Citation

  • Anis Saggaff & Mustapha Muhammad Lawan & Mahmood Md Tahir & Jahangir Mirza, 2016. "Impact of Shear Connector Spacing in Composite Construction Incorporating Cold-Formed Steel Channel Lipped Section," Review of Industrial Engineering Letters, Conscientia Beam, vol. 3(1), pages 11-18.
  • Handle: RePEc:pkp:roiele:v:3:y:2016:i:1:p:11-18:id:2647
    as

    Download full text from publisher

    File URL: https://archive.conscientiabeam.com/index.php/71/article/view/2647/4084
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:pkp:roiele:v:3:y:2016:i:1:p:11-18:id:2647. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Dim Michael (email available below). General contact details of provider: https://archive.conscientiabeam.com/index.php/71/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.