The roles of electrical energy no longer need to be demonstrated since the industrial revolution of 1740 based on the use of new sources of energy, of which electrical energy is considered to be one of the greatest revolutions in the world. Despite this, we must note that electrical energy is changing the habits of human activity and, on the one hand, has consequences on its transport, the large quantities of which are transmitted by power lines, forcing them to operate more and more. more within their limits and unplanned outages increase the risk of instability. Storms, industrial pollution, and lightning strikes are the main causes of these unscheduled outages. In regions with a high keraunic level, the reduction of insulation breakdown due to lightning is, therefore, a major concern for designers and operators of HV lines. It is possible to reduce the number of tripping of power lines due to lightning by the proper installation of ground wires and by the appropriate grounding of pylons. In this article, we focus our research on the analysis of the impact of the earthing of the pylons on the performance of HV lines against lightning strikes. Considering these parameters and using the oldest and simplest analytical model as a time-varying current wave whose model is a difference of two decaying exponentials, we brought into contribution Maxwell's equations, the law of Ohm, telegrapher's equations, transmission line theory, and the FDTD method to model lightning-induced voltages as a function of HVAC tower grounding. This study was carried out on the Liminga-Funa 220 kilovolt alternating line in the DRCongo, located in a region where storm activity and industrial pollution are very high. Thus, the results obtained by simulation show that the peak voltage on the components of the HVAC line is a linear function of the impedance of the earthing of the pylon. The impedance value of the pylon earthing less than or equal to 10 Ohm dampens the atmospheric overvoltage and ensures good coordination of the insulation of the line elements in the event of a lightning strike at the top of the pylon for the first bow. But for the return arc taken in this case, the bypass of the insulator is unavoidable. The fractal dimensions of the results of our programs have been compared with those of the figures obtained experimentally.

Suggested Citation

  • Anthony Bassesuka Sandoka Nzao, 2023. "Analysis of the Influence of the Earthing Resistance of Pylones on the Performance of the HVAC Line Facing Electromagnetic Transitories Lightning," Computer and Information Science, Canadian Center of Science and Education, vol. 16(1), pages 1-25, February.
  • Handle: RePEc:ibn:cisjnl:v:16:y:2023:i:1:p:25
    as

    Download full text from publisher

    File URL: https://ccsenet.org/journal/index.php/cis/article/download/0/0/48070/51654
    Download Restriction: no

    File URL: https://ccsenet.org/journal/index.php/cis/article/view/0/48070
    Download Restriction: no
    ---><---

    More about this item

    JEL classification:

    • R00 - Urban, Rural, Regional, Real Estate, and Transportation Economics - - General - - - General
    • Z0 - Other Special Topics - - General

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:ibn:cisjnl:v:16:y:2023:i:1:p:25. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Canadian Center of Science and Education (email available below). General contact details of provider: https://edirc.repec.org/data/cepflch.html .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.