IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v16y2024i8p3278-d1375752.html
   My bibliography  Save this article

Reverse Engineering of Building Layout Plan through Checking the Setting out of a Building on a Site Using 3D Laser Scanning Technology for Sustainable Building Construction: A Case Study

Author

Listed:
  • Hyunjun Kim

    (Department of Architectural Engineering, Graduate School, Kyonggi University, Suwon 16227, Republic of Korea)

  • Ju-Yong Kim

    (Department of Architectural Engineering, Graduate School, Kyonggi University, Suwon 16227, Republic of Korea)

  • Yoonseok Shin

    (Major of Architectural Engineering, Kyonggi University, Suwon 16227, Republic of Korea)

Abstract

Among smart construction technologies, 3D laser scanning technology is used in a variety of applications, including progress measurement, quantity management, reverse engineering (RE), health monitoring, mechanical electronic plumbing (MEP), and so on, using point clouds data (PCD) in the architecture, engineering, and construction (AEC) field. This technology is one of the important data acquisition technologies in construction status to perform active project management through the complete and accurate three-dimensional and visual judgment of building acts. The surveying work for setting out a building is the first step in constructing a building; the location of the building must match the design plan for a building to be sustainable. This is because, if a location deviation exceeds the permitted range, the building must be demolished and rebuilt. When this happens, sustainable construction management is impossible due to delays in the construction schedule, increased construction costs, waste generation, and so on. The purpose of this study is to investigate a case where the accuracy of setting out a building was measured in the construction stage of a building and the building layout design was modified by RE. Although the foundation construction of the case building was in progress, it was confirmed that the setting out of the building measured using a 3D laser scanner did not match with the building layout plan. Therefore, there was no legal problem even if the layout plan is modified according to the measured results, so the building layout plan was modified through RE. Consequently, it was confirmed that a case building under construction became sustainable through RE, and that sustainable construction management was possible by preventing construction schedule delays, increased construction costs, and waste generation.

Suggested Citation

  • Hyunjun Kim & Ju-Yong Kim & Yoonseok Shin, 2024. "Reverse Engineering of Building Layout Plan through Checking the Setting out of a Building on a Site Using 3D Laser Scanning Technology for Sustainable Building Construction: A Case Study," Sustainability, MDPI, vol. 16(8), pages 1-16, April.
  • Handle: RePEc:gam:jsusta:v:16:y:2024:i:8:p:3278-:d:1375752
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/16/8/3278/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/16/8/3278/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:16:y:2024:i:8:p:3278-:d:1375752. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.