IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v20y2023i4p3220-d1066054.html
   My bibliography  Save this article

Study of Windlass Mechanism in the Lower Limb Using Inertial Sensors

Author

Listed:
  • María José Manfredi-Márquez

    (Podiatry Department, University of Seville, 41004 Sevilla, Spain)

  • Sandra Priscila Tavara-Vidalón

    (Podiatry Department, University of Seville, 41004 Sevilla, Spain)

  • Natalia Tavaruela-Carrión

    (Podiatry Department, University of Seville, 41004 Sevilla, Spain)

  • María Ángeles Gómez Benítez

    (Podiatry Department, University of Seville, 41004 Sevilla, Spain)

  • Lourdes María Fernandez-Seguín

    (Physiotherapy Department, University of Seville, 41009 Sevilla, Spain
    Institute of Biomedicine of Seville, 41013 Seville, Spain)

  • Javier Ramos-Ortega

    (Podiatry Department, University of Seville, 41004 Sevilla, Spain)

Abstract

Aims: This study aimed to quantify the degrees of movement that occur in the lower limb using a kinematic system after taking two measurements of 45° and 60° of extension at the first metatarsophalangeal joint (1st MTPJ) and to test the validity of this sensor system using radiography. Methodology: This was a quasi-experimental test-post-test study with a single intervention group (25 subjects). Four inertial sensors were placed on the proximal phalange of the first toe, dorsum of the foot, medial-lateral of the leg (level of tibia), and medial-lateral of the thigh (level of femur). The extension of the 1st MTPJ produced movements of supination in the foot and rotation at the level of leg and thigh. We studied this mechanism in three situations (relaxed, 45°, and 60°) both with the sensors and with X-rays. Results: With the kinematic system, there was an increase in the range of movement in each of the variables, with a value of p < 0.05. The relationship between the kinematic system and the radiography was tested using Spearman’s rho test, obtaining a correlation coefficient of 0.624 and a value of p < 0.05, and the Bland–Altman graph, with 90% of the cases within the tolerance limits. Conclusions: The extension of the 1st MTPJ generated kinematic changes associated with supination movement in the midfoot and external rotation on the tibia and femur level. Both measurement techniques were very similar in the way that they quantified the degrees of extension of the 1st MTPJ. If we extrapolate this result to the measurement technique used by the inertial sensors, we could affirm that the values recorded in the supination and external rotation movements were reliable.

Suggested Citation

  • María José Manfredi-Márquez & Sandra Priscila Tavara-Vidalón & Natalia Tavaruela-Carrión & María Ángeles Gómez Benítez & Lourdes María Fernandez-Seguín & Javier Ramos-Ortega, 2023. "Study of Windlass Mechanism in the Lower Limb Using Inertial Sensors," IJERPH, MDPI, vol. 20(4), pages 1-8, February.
  • Handle: RePEc:gam:jijerp:v:20:y:2023:i:4:p:3220-:d:1066054
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/20/4/3220/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/20/4/3220/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:20:y:2023:i:4:p:3220-:d:1066054. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.