IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v20y2023i2p1649-d1037923.html
   My bibliography  Save this article

Impact of Plastic-Wrap Properties and Cleaning Intervals on the Disinfection of Elevator Buttons

Author

Listed:
  • Shin-Huei Kuo

    (Department of Internal Medicine, Kaohsiung Municipal Ta-Tung Hospital, Kaohsiung Medical University, No. 68, Jhonghua 3rd Road, Kaohsiung 80145, Taiwan
    Division of Infectious Diseases, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Road, Kaohsiung 80708, Taiwan)

  • Tzu-Yin Liu

    (Infection Control Office, Kaohsiung Municipal Ta-Tung Hospital, Kaohsiung Medical University, No. 68, Jhonghua 3rd Road, Kaohsiung 80145, Taiwan)

  • Tun-Chieh Chen

    (Department of Internal Medicine, Kaohsiung Municipal Ta-Tung Hospital, Kaohsiung Medical University, No. 68, Jhonghua 3rd Road, Kaohsiung 80145, Taiwan
    Division of Infectious Diseases, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Road, Kaohsiung 80708, Taiwan
    Infection Control Office, Kaohsiung Municipal Ta-Tung Hospital, Kaohsiung Medical University, No. 68, Jhonghua 3rd Road, Kaohsiung 80145, Taiwan
    School of Medicine, College of Medicine, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Road, Kaohsiung 80708, Taiwan)

  • Chih-Jen Yang

    (School of Medicine, College of Medicine, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Road, Kaohsiung 80708, Taiwan
    Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Road, Kaohsiung 80708, Taiwan)

  • Yen-Hsu Chen

    (Division of Infectious Diseases, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Road, Kaohsiung 80708, Taiwan
    School of Medicine, College of Medicine, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Road, Kaohsiung 80708, Taiwan
    School of Medicine, College of Medicine, National Sun Yat-sen University, No. 70, Lien-Hai Road, Kaohsiung 80424, Taiwan)

Abstract

Fomite transmission is a possible route by which different pathogens spread within facilities. In hospital settings, elevator buttons are widely observed to be covered with various types of plastic wraps; however, limited information is available concerning the impact of different plastic materials on cleaning. Our study aimed to identify which plastic material is suitable for the coverage of elevator buttons and the optimal intervals for their cleaning. We tested six plastic covers, including polyethylene (PE), polymethylpentene (PMP), polyvinyl chloride (PVD), and polyvinylidene chloride (PVDC) plastic wraps; a thermoplastic polyurethane (TPU) keyboard cover; and a polyethylene terephthalate-ethylene vinyl acetate (PET-EVA) laminating film, which are plastic films. The bioburden on the elevator buttons at different time intervals was measured using an adenosine triphosphate (ATP) bioluminescence assay. Our results show that wraps made of PVDC had superior durability compared with those of PMP, PVC, and PVDC, in addition to the lowest detectable ATP levels among the six tested materials. Regarding different button locations, the highest ATP values were found in door-close buttons followed by door-open, and first-floor buttons after one- and three-hour intervals ( p = 0.024 and p < 0.001, respectively). After routine disinfection, the ATP levels of buttons rapidly increased after touching and became more prominent after three hours ( p < 0.05). Our results indicate that PVDC plastic wraps have adequate durability and the lowest residual bioburden when applied as covers for elevator buttons. Door-close and -open buttons were the most frequently touched sites, requiring more accurate and precise disinfection; therefore, cleaning intervals of no longer than three hours may be warranted.

Suggested Citation

  • Shin-Huei Kuo & Tzu-Yin Liu & Tun-Chieh Chen & Chih-Jen Yang & Yen-Hsu Chen, 2023. "Impact of Plastic-Wrap Properties and Cleaning Intervals on the Disinfection of Elevator Buttons," IJERPH, MDPI, vol. 20(2), pages 1-9, January.
  • Handle: RePEc:gam:jijerp:v:20:y:2023:i:2:p:1649-:d:1037923
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/20/2/1649/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/20/2/1649/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Agata Jabłońska-Trypuć & Marcin Makuła & Maria Włodarczyk-Makuła & Elżbieta Wołejko & Urszula Wydro & Lluis Serra-Majem & Józefa Wiater, 2022. "Inanimate Surfaces as a Source of Hospital Infections Caused by Fungi, Bacteria and Viruses with Particular Emphasis on SARS-CoV-2," IJERPH, MDPI, vol. 19(13), pages 1-22, July.
    2. Jana Koscova & Zuzana Hurnikova & Juraj Pistl, 2018. "Degree of Bacterial Contamination of Mobile Phone and Computer Keyboard Surfaces and Efficacy of Disinfection with Chlorhexidine Digluconate and Triclosan to Its Reduction," IJERPH, MDPI, vol. 15(10), pages 1-9, October.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Sunhee Park & Beomsoo Kim & Kyoung A. Kim, 2021. "Preventive Behavioral Insights for Emerging Adults: A Survey during the COVID-19 Pandemic," IJERPH, MDPI, vol. 18(5), pages 1-10, March.
    2. Gabriele Cervino & Luca Fiorillo & Giovanni Surace & Valeria Paduano & Maria Teresa Fiorillo & Rosa De Stefano & Riccardo Laudicella & Sergio Baldari & Michele Gaeta & Marco Cicciù, 2020. "SARS-CoV-2 Persistence: Data Summary up to Q2 2020," Data, MDPI, vol. 5(3), pages 1-16, September.
    3. Andrea Guridi & Elena Sevillano & Iñigo de la Fuente & Estibaliz Mateo & Elena Eraso & Guillermo Quindós, 2019. "Disinfectant Activity of A Portable Ultraviolet C Equipment," IJERPH, MDPI, vol. 16(23), pages 1-11, November.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:20:y:2023:i:2:p:1649-:d:1037923. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.