IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i10p3453-d358603.html
   My bibliography  Save this article

Direct Enantiomeric Separation and Determination of Hexythiazox Enantiomers in Environment and Vegetable by Reverse-Phase High-Performance Liquid Chromatography

Author

Listed:
  • Ping Zhang

    (Key Laboratory of Entomology and Pest Control Engineering, College of Plant Protection, Southwest University, Chongqing 400715, China
    Academy of Agricultural Sciences, Southwest University, Chongqing 400715, China
    State Cultivation Base of Crop Stress Biology for Southern Mountainous Land of Southwest University, Southwest University, Chongqing 400715, China)

  • Sheng Wang

    (Key Laboratory of Entomology and Pest Control Engineering, College of Plant Protection, Southwest University, Chongqing 400715, China
    Academy of Agricultural Sciences, Southwest University, Chongqing 400715, China)

  • Dongmei Shi

    (Key Laboratory of Entomology and Pest Control Engineering, College of Plant Protection, Southwest University, Chongqing 400715, China
    Academy of Agricultural Sciences, Southwest University, Chongqing 400715, China)

  • Yangyang Xu

    (Key Laboratory of Entomology and Pest Control Engineering, College of Plant Protection, Southwest University, Chongqing 400715, China
    Academy of Agricultural Sciences, Southwest University, Chongqing 400715, China)

  • Furong Yang

    (Key Laboratory of Entomology and Pest Control Engineering, College of Plant Protection, Southwest University, Chongqing 400715, China
    Academy of Agricultural Sciences, Southwest University, Chongqing 400715, China)

  • Xile Deng

    (Key Laboratory for Biology and Control of Weeds, Biotechnology Research Institute, Hunan Academy of Agricultural Sciences, Changsha 410125, China)

  • Yuhan He

    (Key Laboratory of Entomology and Pest Control Engineering, College of Plant Protection, Southwest University, Chongqing 400715, China
    Academy of Agricultural Sciences, Southwest University, Chongqing 400715, China)

  • Lin He

    (Key Laboratory of Entomology and Pest Control Engineering, College of Plant Protection, Southwest University, Chongqing 400715, China
    Academy of Agricultural Sciences, Southwest University, Chongqing 400715, China
    State Cultivation Base of Crop Stress Biology for Southern Mountainous Land of Southwest University, Southwest University, Chongqing 400715, China)

Abstract

In the present study, the direct enantiomeric separation of hexythiazox enantiomers on Lux cellulose-1, Lux cellulose-2, Lux cellulose-3, Lux cellulose-4, Lux amylose-1 and Chirapak IC chiral columns were carefully investigated by reverse-phase high-performance liquid chromatography (RP-HPLC). Acetonitrile/water and methanol/water were used as mobile phase at a flow rate of 0.8 mL·min −1 . The effects of chiral stationary phase, temperature, thermodynamic parameters, mobile phase component and mobile phase ratio on hexythiazox enantiomers separation were fully evaluated. Hexythiazox enantiomers received a baseline separation on the Lux cellulose-3 column with a maximum resolution of R s = 2.09 (methanol/water) and R s = 2.74 (acetonitrile/water), respectively. Partial separations were achieved on other five chiral columns. Furthermore, Lux amylose-1 and Chirapak IC had no separation ability for hexythiazox enantiomers when methanol/water was used as mobile phase. Temperature study indicated that the capacity factor (k) and resolution factor (R s ) decreased with column temperature increasing from 10 °C to 40 °C. The enthalpy (ΔH) and entropy (ΔS) involved in hexythiazox separation were also calculated and demonstrated the lower temperature contributed to better separation resolution. Moreover, the residue analytical method for hexythiazox enantiomers in the environment (soil and water) and vegetable (cucumber, cabbage and tomato) were also established with reliable accuracy and precision under reverse-phase HPLC condition. Such results provided a baseline separation method for hexythiazox enantiomers under reverse-phase conditions and contributed to an environmental and health risk assessment of hexythiazox at enantiomer level.

Suggested Citation

  • Ping Zhang & Sheng Wang & Dongmei Shi & Yangyang Xu & Furong Yang & Xile Deng & Yuhan He & Lin He, 2020. "Direct Enantiomeric Separation and Determination of Hexythiazox Enantiomers in Environment and Vegetable by Reverse-Phase High-Performance Liquid Chromatography," IJERPH, MDPI, vol. 17(10), pages 1-15, May.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:10:p:3453-:d:358603
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/10/3453/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/10/3453/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:10:p:3453-:d:358603. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.