A Transformer Partial Discharge Measurement System Based on Fluorescent Fiber

Author

Listed:
  • Ju Tang

    (State Key Laboratory of Power Transmission Equipment & System Security and New Technology, College of Electrical Engineering, Chongqing University, Chongqing 400030, China)

  • Jiabin Zhou

    (State Key Laboratory of Power Transmission Equipment & System Security and New Technology, College of Electrical Engineering, Chongqing University, Chongqing 400030, China
    Shandong Electrical Power Institute, No.500, Round 2 South Street, Center District, Jinan 250002, Shandong, China)

  • Xiaoxing Zhang

    (State Key Laboratory of Power Transmission Equipment & System Security and New Technology, College of Electrical Engineering, Chongqing University, Chongqing 400030, China)

  • Fan Liu

    (State Key Laboratory of Power Transmission Equipment & System Security and New Technology, College of Electrical Engineering, Chongqing University, Chongqing 400030, China)

Abstract

Based on the physical phenomena of optical effects produced by the partial discharge (PD) and on the characteristics of fluorescent fiber sensing of weak fluorescent signals, a PD measurement system using a fluorescent fiber sensor was designed. The main parameters of the sensing system were calculated, an experimental testing platform for PD simulation in the lab was established, and PD signals were then detected through ultra-high frequency (UHF) and optical methods under a needle-plate discharge model. PD optical pulses in transformer oil contained signal-peak and multi-peak pulse waveforms. Compared with UHF detection results, the number of PD pulses and the elapsed PD pulse phase time revealed a good corresponding relationship. However, PD signal amplitudes presented the opposite, thus indicating that PD UHF signals reflected pulse amplitude value, whereas PD optical signals reflected pulse energy magnitude. The n-u-φ three-dimensional distributions indicated that most of the PD signals concentrated in the nearby industrial frequency voltage peak value. Overall, the proposed fluorescent fiber sensing system design can be used successfully in transformer PD signal detection.

Suggested Citation

  • Ju Tang & Jiabin Zhou & Xiaoxing Zhang & Fan Liu, 2012. "A Transformer Partial Discharge Measurement System Based on Fluorescent Fiber," Energies, MDPI, vol. 5(5), pages 1-13, May.
  • Handle: RePEc:gam:jeners:v:5:y:2012:i:5:p:1490-1502:d:17773
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/5/5/1490/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/5/5/1490/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Jian Li & Xudong Li & Lin Du & Min Cao & Guochao Qian, 2016. "An Intelligent Sensor for the Ultra-High-Frequency Partial Discharge Online Monitoring of Power Transformers," Energies, MDPI, vol. 9(5), pages 1-15, May.
    2. Ming Ren & Ming Dong & Jialin Liu, 2016. "Statistical Analysis of Partial Discharges in SF 6 Gas via Optical Detection in Various Spectral Ranges," Energies, MDPI, vol. 9(3), pages 1-15, March.
    3. Shuaibing Li & Guoqiang Gao & Guangcai Hu & Bo Gao & Haojie Yin & Wenfu Wei & Guangning Wu, 2017. "Influences of Traction Load Shock on Artificial Partial Discharge Faults within Traction Transformer—Experimental Test for Pattern Recognition," Energies, MDPI, vol. 10(10), pages 1-17, October.
    4. Luis Hernández-Callejo, 2019. "A Comprehensive Review of Operation and Control, Maintenance and Lifespan Management, Grid Planning and Design, and Metering in Smart Grids," Energies, MDPI, vol. 12(9), pages 1-50, April.
    5. Tianhui Li & Xianhai Pang & Boyan Jia & Yanwei Xia & Siming Zeng & Hongliang Liu & Hao Tian & Fen Lin & Dan Wang, 2020. "Detection and Diagnosis of Defect in GIS Based on X-ray Digital Imaging Technology," Energies, MDPI, vol. 13(3), pages 1-18, February.
    6. Tianhui Li & Mingzhe Rong & Xiaohua Wang & Jin Pan, 2017. "Experimental Investigation on Propagation Characteristics of PD Radiated UHF Signal in Actual 252 kV GIS," Energies, MDPI, vol. 10(7), pages 1-12, July.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:5:y:2012:i:5:p:1490-1502:d:17773. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.