IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v17y2024i6p1443-d1358632.html
   My bibliography  Save this article

Common-Mode Voltage Reduction Method Based on Variable Sampling Frequency Finite Control Set-Model Predictive Control for PMSM Drive Systems

Author

Listed:
  • Yoon-Seong Lee

    (Department of Electrical and Computer Engineering, College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea)

  • Kyoung-Min Choo

    (Electric Propulsion Research Center, Korea Electrotechnology Research Institute (KERI), Changwon 51541, Republic of Korea)

  • Chang-Hee Lee

    (Dawonsys Co., Ltd., Anyang 15655, Republic of Korea)

  • Chang-Gyun An

    (Department of Electrical and Computer Engineering, College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea)

  • Junsin Yi

    (Department of Electrical and Computer Engineering, College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea)

  • Chung-Yuen Won

    (Department of Electrical and Computer Engineering, College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea)

Abstract

In this article, a finite control set-model predictive control (FCS-MPC) with variable sampling time is proposed. A zero-voltage vector appears in the dead time between specific voltage vectors, resulting in an unintentionally large common-mode voltage. Herein, a large common-mode voltage was suppressed, and the load current was controlled using a voltage vector combination that did not cause a zero-voltage vector in dead time. Additionally, to improve the total harmonic distortion (THD) of the load current, the intersection of the predicted current and the command current by all the volage vectors (VVs) in the combination is confirmed. The VV where the intersection occurs is selected as the optimal VV. This optimal VV is applied to the point where the predicted current and the reference current intersect. The applicable range of the sampling time should be selected by considering the calculation time and number of switching. Through the proposed FCS-MPC strategy, not only can the common-mode voltage be limited to within ±Vdc/6, but an improved THD can also be obtained compared to the existing method using fixed sampling. The proposed method was verified through PSIM simulation and experimental results.

Suggested Citation

  • Yoon-Seong Lee & Kyoung-Min Choo & Chang-Hee Lee & Chang-Gyun An & Junsin Yi & Chung-Yuen Won, 2024. "Common-Mode Voltage Reduction Method Based on Variable Sampling Frequency Finite Control Set-Model Predictive Control for PMSM Drive Systems," Energies, MDPI, vol. 17(6), pages 1-19, March.
  • Handle: RePEc:gam:jeners:v:17:y:2024:i:6:p:1443-:d:1358632
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/17/6/1443/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/17/6/1443/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:6:p:1443-:d:1358632. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.