IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v15y2022i21p8166-d960558.html
   My bibliography  Save this article

Tracer Gas Test and CFD Analysis of Semiconductor Gas Box for Flammable Gas Leakage

Author

Listed:
  • Shin-eui Kim

    (Department of Environmental Engineering, Ajou University, Suwon 16499, Korea
    These authors contributed equally to this work.)

  • Kwangho Lee

    (Department of Environmental Engineering, Ajou University, Suwon 16499, Korea
    These authors contributed equally to this work.)

  • Chankyu Kang

    (School of Social Safety System Engineering, Research Center for Safety and Health, Hankyong National University, Anseong 17579, Korea)

  • Seungho Jung

    (Department of Environmental Engineering, Ajou University, Suwon 16499, Korea)

Abstract

Semiconductor manufacturing is performed through unit processes that use various chemicals and facilities. In particular, flammable gases, such as H 2 , NH 3 , and CH 4 , are used, and there is a risk of explosion when such gases leak. In this study, computational fluid dynamics (CFD) simulation and a “tracer gas test” according to the SEMI (Semiconductor Equipment and Materials International) S6 Environmental, Health, and Safety Guideline for Exhaust Ventilation of Semiconductor Manufacturing Equipment specification were performed during the leakage of hydrogen, a highly flammable gas used in the etching process of a gas box in the semiconductor industry. The CFD simulation was conducted to investigate the safety of semiconductor production facilities in relation to the explosion risk. Flow analysis was performed for the interior of a gas box used in the etching process. A steady-state analysis was performed to predict the concentration range of the explosion limit in the case of continuous hydrogen gas leakage. The interior of the gas box used in the simulation was modeled, and the ventilation flow rate, which has a significant impact on the leakage gas concentration distribution, obtained from experiments was used. The lower flammability limit (LFL) value of the leaked gas was 4% based on H 2 , and LFL/4 (25% of the LFL) was analyzed as the explosion limit concentration according to the acceptance criteria of the SEMI S6 tracer gas test. To validate the CFD simulation, a tracer gas test was performed according to SEMI S6. A mixture of hydrogen (5%) and nitrogen (95%) was used as the tracer gas. The flow rate was controlled by a gas regulator valve and measured using an Aalborg mass flow meter. The measured concentration of the tracer gas was calculated using the equivalent release concentration, which was calculated when 100% of the hydrogen was released, and the risk was assessed by comparing it with the LFL/4 of H 2 .

Suggested Citation

  • Shin-eui Kim & Kwangho Lee & Chankyu Kang & Seungho Jung, 2022. "Tracer Gas Test and CFD Analysis of Semiconductor Gas Box for Flammable Gas Leakage," Energies, MDPI, vol. 15(21), pages 1-15, November.
  • Handle: RePEc:gam:jeners:v:15:y:2022:i:21:p:8166-:d:960558
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/15/21/8166/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/15/21/8166/
    Download Restriction: no
    ---><---

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:21:p:8166-:d:960558. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.