IDEAS home Printed from https://ideas.repec.org/a/caa/jnlvet/v63y2018i2id115-2017-vetmed.html
   My bibliography  Save this article

Restrainer exposure to scatter radiation in practical small animal radiography measured using thermoluminescent dosimeters

Author

Listed:
  • H. Oh

    (College of Veterinary Medicine, Chonbuk National University, Iksan, Republic of Korea)

  • S. Sung

    (College of Veterinary Medicine, Chonbuk National University, Iksan, Republic of Korea)

  • S. Lim

    (College of Veterinary Medicine, Chonbuk National University, Iksan, Republic of Korea)

  • Y. Jung

    (Research Promotion Team, Office of Research Management, Korea University, Seoul, Republic of Korea)

  • Y. Cho

    (College of Health Sciences, Cheongju University, Cheongju, Republic of Korea)

  • K. Lee

    (College of Veterinary Medicine, Chonbuk National University, Iksan, Republic of Korea)

Abstract

This study was aimed at estimating restrainer exposure to scatter radiation in veterinary radiography using thermoluminescent dosimeters (TLDs) in different positions, and at different anatomic regions. A prospective study was conducted to measure exposure dose of two restrainers: A (cathode side) and B (anode side), and an observer C (at a 1-meter distance from the X-ray table) over two months. Protective devices included panorama mask, thyroid shield and arm shield. TLDs were placed on the inside and outside of the protective gear at five different anatomic sites (eye, thyroid, breast, gonad and arm). The study data consisted of 778 exposures, 82 patients (78 dogs, four cats), a mean kVp of 58.7 and a mean mAs of 11.4. The doses (outside the shield/inside the shield, in mSv) measured by restrainers A, B and C were eye (3.04/0.42), (2.29/0.17), (0.55/0.01), thyroid (2.93/0.01), (1.97/0.01), (0.19/0.01), breast (1.01/0.04), (0.73/0.01), (0.32/0.01), gonad (0.07/0.01), (0.01/0.01), (0.16/0.01) and arm (2.81/1.43), (1.17/0.01), (0.08/0.01), respectively. This study describes the extent of occupational radiation exposure in small animal radiography. The exposure dose for eyes outside lead protection showed the highest value in all participants. With lead protection, the reduction in the exposure dose of eyes was significant (A: 86%, B: 93%, C: 98%), and the highest reduction was 99% in the thyroid region. These results suggest the necessity of radiation shields in manual restraint, particularly for eye protection.

Suggested Citation

  • H. Oh & S. Sung & S. Lim & Y. Jung & Y. Cho & K. Lee, 2018. "Restrainer exposure to scatter radiation in practical small animal radiography measured using thermoluminescent dosimeters," Veterinární medicína, Czech Academy of Agricultural Sciences, vol. 63(2), pages 81-86.
  • Handle: RePEc:caa:jnlvet:v:63:y:2018:i:2:id:115-2017-vetmed
    DOI: 10.17221/115/2017-VETMED
    as

    Download full text from publisher

    File URL: http://vetmed.agriculturejournals.cz/doi/10.17221/115/2017-VETMED.html
    Download Restriction: free of charge

    File URL: http://vetmed.agriculturejournals.cz/doi/10.17221/115/2017-VETMED.pdf
    Download Restriction: free of charge

    File URL: https://libkey.io/10.17221/115/2017-VETMED?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Jeongsu An & Sohee Lim & Seunghee Lee & Hyeona Kim & Kyungjun Min & Youngkwon Cho & Kichang Lee, 2019. "Evaluation of radiation exposure from fluoroscopic examination in small animal veterinary staff using thermoluminescent dosimeters," Veterinární medicína, Czech Academy of Agricultural Sciences, vol. 64(6), pages 266-270.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:caa:jnlvet:v:63:y:2018:i:2:id:115-2017-vetmed. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Ivo Andrle (email available below). General contact details of provider: https://www.cazv.cz/en/home/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.