IDEAS home Printed from https://ideas.repec.org/a/caa/jnlvet/v61y2016i7id168-2015-vetmed.html
   My bibliography  Save this article

Use of castor bean polymer in developing a new technique for tibial tuberosity advancement for cranial cruciate ligament rupture correction in dogs

Author

Listed:
  • R.M. Medeiros

    (Sao Paulo State University, Jaboticabal Campus, Jaboticabal, Sao Paulo, Brazil)

  • M.A.M. Silva

    (College of Agronomy and Veterinary Medicine, University of Passo Fundo, Passo Fundo, Rio Grande do Sul, Brazil)

  • P.P.M. Teixeira

    (Veterinary Hospital, Para Federal University, Castanhal, Para, Brazil)

  • L.G.G.G. Dias

    (Sao Paulo State University, Jaboticabal Campus, Jaboticabal, Sao Paulo, Brazil)

  • D.G. Chung

    (Sao Paulo State University, Jaboticabal Campus, Jaboticabal, Sao Paulo, Brazil)

  • C.C. Zani

    (Sao Paulo State University, Jaboticabal Campus, Jaboticabal, Sao Paulo, Brazil)

  • M.A.R. Feliciano

    (Sao Paulo State University, Jaboticabal Campus, Jaboticabal, Sao Paulo, Brazil)

  • M.E.B.A.M. Da Conceicao

    (Sao Paulo State University, Jaboticabal Campus, Jaboticabal, Sao Paulo, Brazil)

  • M.R.F. Machado

    (Sao Paulo State University, Jaboticabal Campus, Jaboticabal, Sao Paulo, Brazil)

  • A.G. Rocha

    (Sao Paulo State University, Jaboticabal Campus, Jaboticabal, Sao Paulo, Brazil)

  • G.O. Chierice

    (Sao Carlos Chemistry Institute, Sao Paulo University, Sao Paulo, Brazil)

  • L.N. Coutinho

    (Animal Health and Production Institute, Amazonia Rural Federal University, Belem, Para, Brazil)

  • J.G. Padilha Filho

    (Sao Paulo State University, Jaboticabal Campus, Jaboticabal, Sao Paulo, Brazil)

Abstract

The purpose of the current study was to develop a new tibial tuberosity advancement (TTA) technique, by replacing the original titanium cage with a Ricinus communis polyurethane resin-made wedge polymer. The implants were manufactured using the same size and angles of the original titanium cages, though larger distally. The modified TTA technique (TTAm) was performed in 42 knees of 35 dogs diagnosed with rupture of the cranial cruciate ligament (RCCL). Animals were submitted to radiographic and gait assessments preoperatively, early postoperatively and following 30, 60, 90 and 120 days. All animals exhibited good clinical outcome. There were no cases of impaired healing or bone resorption until 120 days postoperatively and there was no patient with patellar distress after TTAm. Scores of gait evaluation revealed differences between time points. There were also differences between the evaluations of control and pre- and post-operative times. However, there was no difference among the assessment of 30 days and the following time points. The use of the polyurethane polymer for TTAm was advantageous, not only due to biocompatibility and osseointegration, but also for providing easy handling; it can be moulded intra-operatively if necessary. Moreover, it allows precise adaptation to the osteotomy site, as opposed to the original TTA metallic implants, which cannot be moulded. It is suggested that incision lengths for TTAm are slightly shorter than those required for the conventional TTA as this requires the distal fixation of the plate at the beginning of the middle third of the body of the tibia. The TTAm does not require the use of fixation plates and it is performed only at the cranial aspect of the tibia. The method of attachment of the tibial tuberosity in the craniocaudal direction was effective. The setting associated with the use of the polyurethane polymer allowed simplification of the technique for easier implementation, and the amount of implant material required to perform TTAm was reduced in comparison to the conventional TTA. This technique can be used for treating the knees of dogs with RCCL, and provides for easy execution, less invasiveness to the tissues of the knee joint and more versatility in comparison to conventional TTA.

Suggested Citation

  • R.M. Medeiros & M.A.M. Silva & P.P.M. Teixeira & L.G.G.G. Dias & D.G. Chung & C.C. Zani & M.A.R. Feliciano & M.E.B.A.M. Da Conceicao & M.R.F. Machado & A.G. Rocha & G.O. Chierice & L.N. Coutinho & J.G, 2016. "Use of castor bean polymer in developing a new technique for tibial tuberosity advancement for cranial cruciate ligament rupture correction in dogs," Veterinární medicína, Czech Academy of Agricultural Sciences, vol. 61(7), pages 382-388.
  • Handle: RePEc:caa:jnlvet:v:61:y:2016:i:7:id:168-2015-vetmed
    DOI: 10.17221/168/2015-VETMED
    as

    Download full text from publisher

    File URL: http://vetmed.agriculturejournals.cz/doi/10.17221/168/2015-VETMED.html
    Download Restriction: free of charge

    File URL: http://vetmed.agriculturejournals.cz/doi/10.17221/168/2015-VETMED.pdf
    Download Restriction: free of charge

    File URL: https://libkey.io/10.17221/168/2015-VETMED?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:caa:jnlvet:v:61:y:2016:i:7:id:168-2015-vetmed. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Ivo Andrle (email available below). General contact details of provider: https://www.cazv.cz/en/home/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.