Performance-Based Design Assessment of Temperature Tenability Condition in a Hotel Atrium

Author

Listed:
  • John Reuben Kisilu

    (MSc Student, Department of Mechanical and Manufacturing Engineering, University of Nairobi)

  • Dr Ernest Odhiambo (Ph.D)

    (Department of Mechanical and Manufacturing Engineering, University of Nairobi)

  • Dr Reuben Mwanza Kivindu (Ph.D)

    (Department of Mechanical and Manufacturing Engineering, University of Nairobi)

Abstract

Fire safety risk assessment to prevent loss of human life and property is necessary for complex structures where the traditional prescriptive designs are inapplicable. Maintaining tenable temperature conditions is essential for the safe evacuation of building occupants. This study considered British Standards (BS) 7974 and the Code of Practice for Fire Precautions in Buildings to analyze the temperature tenability conditions in the hotel atrium through a performance-based design approach. Further, the Computational Fluid Dynamics (CFD) code, Pyrosim, a Graphical User Interface (GUI) of the Fire Dynamics Simulator (FDS), was utilized to simulate a constant Heat Release Rate (HRR) steady state design fire of 5 Megawatts (MW) igniting from the hotel brasserie (ground floor) within the atrium. The researcher used the big design fire of 5MW to generalize the results to similar fires in similar structures. The objective was to conduct a fire safety risk assessment to prevent loss of property and fatalities by activating a smoke management control system with a ‘what if’ condition when the fire suppression system failed to start. Temperature data was collected through the statistical steady state profile, smoke layer temperatures, thermocouples, and 2-dimensional slice temperature recordings. The ground floor, the fire source, was found to have untenable conditions for human survival with temperatures above 2250C, as confirmed by thermocouple and steady-state temperature profile readings. Other floors demonstrated tenable conditions for human survival with temperatures below 400C due to the effect of natural vents and mechanical extractors, which extracted the hot smoke at a rate of 15m/s. The temperature recordings from this study compared well with those from Chew and Liew’s (2000) Computational Fluid Dynamics results, which had fire igniting within the atrium, without sprinklers, and had mechanical extraction fans and a constant Heat Release Rate of 5 Megawatts (MW). The results indicated that the smoke control management system maintained tenable temperature conditions within the hotel atrium, even without the fire suppression system through sprinklers. Considering the design fire size was 5 MW, which was significantly big, the results could be generalized for other hotels or structures with similar designs.

Suggested Citation

  • John Reuben Kisilu & Dr Ernest Odhiambo (Ph.D) & Dr Reuben Mwanza Kivindu (Ph.D), 2024. "Performance-Based Design Assessment of Temperature Tenability Condition in a Hotel Atrium," International Journal of Research and Scientific Innovation, International Journal of Research and Scientific Innovation (IJRSI), vol. 11(3), pages 460-474, March.
  • Handle: RePEc:bjc:journl:v:11:y:2024:i:3:p:460-474
    as

    Download full text from publisher

    File URL: https://www.rsisinternational.org/journals/ijrsi/digital-library/volume-11-issue-3/460-474.pdf
    Download Restriction: no

    File URL: https://rsisinternational.org/journals/ijrsi/articles/performance-based-design-assessment-of-temperature-tenability-condition-in-a-hotel-atrium/
    Download Restriction: no
    ---><---

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:bjc:journl:v:11:y:2024:i:3:p:460-474. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Dr. Renu Malsaria (email available below). General contact details of provider: https://www.rsisinternational.org/journals/ijrsi/ .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.