IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v296y2024ics0360544224008247.html
   My bibliography  Save this article

Grey-box model-based demand side management for rooftop PV and air conditioning systems in public buildings using PSO algorithm

Author

Listed:
  • Sun, Yue
  • Luo, Zhiwen
  • Li, Yu
  • Zhao, Tianyi

Abstract

As the major power consumer in buildings, Heating, ventilation and air conditioning (HVAC) systems can significantly contribute to the economical operation of the power system during the peak periods in summer or winter, by flexibly responding to the grid demands. Indoor air temperature set-point resetting is a typical passive demand response (DR) control strategy that have potentials to be widely implemented by inverter air conditioners in residential buildings. However, in the existing small and medium-size public buildings, the compressor motor of HVAC systems mostly does not allow for stepless speed changes. This means that the indoor temperature set-point resetting strategy may results in frequent on/off switching of the chiller plant, leading to a compromised lifespan. Although rooftop photovoltaic systems (PVs) are expected to be widely adopted in new buildings, their potential for peak load shaving or valley load filling has received limited investigation. This study proposes a grey-box model-based demand side management (DSM) method for variable air volume systems (VAVs) and rooftop PVs in public buildings. The DSM method utilizes the particle swarm optimization (PSO) algorithm to determine optimal indoor air temperature and/or evaporator outlet water temperature set-point schedules for the VAVs, as well as optimal charging/discharging schedules for the storage battery of rooftop PVs. This approach aims to reduce the peak power demands of the integrated system without causing severe thermal discomfort, increasing chiller mechanical costs (refers to frequent on/off switching of the chiller plant in this paper), or overcharging/over-discharging of storage batteries. The results of case studies demonstrate that the strategy of co-resetting indoor air temperature – evaporator outlet water temperature set-points outperforms the indoor air temperature set-point resetting strategy in terms of both peak power demands reduction and mechanical cost saving when applied to the VAVs in low performance buildings. In comparison, for the VAVs installed in normal buildings, both the strategies yield significant decreases in peak power demands and mechanical cost by fully utilizing the thermal capacity of the building internal thermal mass. Furthermore, by implementing the DSM method for rooftop PVs, the integrated system can achieve zero or near-zero net power demands during the DR periods. The proposed DSM method can also be utilized in valley load filling programs to facilitate the accommodation of renewable energy.

Suggested Citation

  • Sun, Yue & Luo, Zhiwen & Li, Yu & Zhao, Tianyi, 2024. "Grey-box model-based demand side management for rooftop PV and air conditioning systems in public buildings using PSO algorithm," Energy, Elsevier, vol. 296(C).
  • Handle: RePEc:eee:energy:v:296:y:2024:i:c:s0360544224008247
    DOI: 10.1016/j.energy.2024.131052
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544224008247
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2024.131052?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:296:y:2024:i:c:s0360544224008247. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.